background image

6

Mareli Systems

The joint operation of the system which the automated pellet burner applies to / depends on:

• 

Heat output to which the burner is set;

• 

The heating surfaces of the heater, for which it is intended.

• 

The seal degree of the door and covers of the combustion chamber (condition of sealing ropes);

• 

Chimney draught;

Good chimney draught is essential for proper functioning of the heating system. Boiler capacity and eco-

nomical operation depend largely on it. The heater can only be connected to a chimney with a good draught.

Attention: Suffocation hazard due to lack of oxygen in the installation room.

• 

Ensure sufficient fresh air supply through holes out.

• 

Risk of injury/damage to equipment due to lack of combustion air can lead to tar and noxious gas for-

mation. 

• 

Ensure sufficient fresh air supply through holes out. 

• 

Notify the user of the installation that these holes must remain open.

NOTES:

When using the circulation pump for the transmission of heat energy from the hot water boiler to the heating 

system,d it is not recommended that the return („cold “) water’s temperature is lower than 60oC. A local (in 

the heat exchanger of the boiler) over-cooling of flue gases and condensing water vapour is possible, which is 

one of the end products of fuel combustion.

 Continued operation of the burner is not recommended when the heat rating is less than 50%, since such 

operating modes are not efficient and not cost effective, unless the combustion process is not set up exactly in 

such operating mode.

EXPLANATION

: If the boiler has to operate in a heat power mode which is lower than 50%, it is recom-

mended that a heat accumulator is installed to the heating system which to ensure a reliable, economical, and 

efficient operation of the boiler-burner system in the installation.

Why is regular maintenance important? 

Heating systems should be maintained on a regular basis for the following reasons:

• 

To maintain high efficiency and to operate the heating system economically (with low fuel consumption);

• 

Achieving high safety of operation;

• 

Achieving high environment-friendly combustion;

5. Pellet burner cleaning

The appliance must be cleaned regularly for long and good operation of the pellet burner. Cleaning is done 

when the burner is stopped and switched off from the mains. The more qualitative the pellets used are, the 

longer the intervals between cleaning will be.

The main elements in the burner to be cleaned are the grate and the photo sensor. 

It is mandatory daily cleaning of the basin. Cleaning takes about 5 minutes.

Cleaning sequence:

1.  Turn off the burner.

2.  Wait for the fan to blow out and cool down the burner. The 

display will show OFF.

3.  Switch to OFF the power supply button.

4.  Open the boiler door.

5.  Using gloves or pliers (temperature is still high), remove the 

grate and clean it.

6.  Place the grate back into the burner.

7.  Make sure the basin stops are in position. Improper installa-

tion will result in auto-shut off of the burner thereafter.

8.  Switch to ON the power supply button.

9.  Start the burner. 

Clean the photo sensor once per every 2 months or more often if necessary. Simply open the top cover of the 

burner by unscrewing the fixing screws. The photo sensor is located in the upper left corner. Remove the fixing 

screw and clean with a dry soft cloth. Check the fan, and clean it if necessary.

Do not use any cleaning agents.!

Boiler:

 Clean the ashes from the boiler with a brush and remove the soot.

Pellet hopper:

 Clean the pellet hopper periodically. When using lower quality pellets, they generate ash, which 

accumulates on the hopper base and impedes the passage of the pellets.

Summary of Contents for SMB 35

Page 1: ...SMB 35 Pellet burner Assembly and exploitation manual Mareli Systems...

Page 2: ...y an adult who is familiar with the operating conditions Introduction of inflammable liquids in room with a working burner is strictly prohibited Children should not be left unattended in the room whe...

Page 3: ...lied to the flexible tube The flexible tube is made of special heat resistant material which in the case of combustion does not emit toxic substances and connects the auger and pellet burner End view...

Page 4: ...ach a pellet burner to the door through M8 screws which are screwed where the thread is made on the door itself which holds the burner to the door Explanation It must be checked whether sealing ropes...

Page 5: ...about 3 hours for the chimney to be warmed up and measure the draught Install addition al chimney fan controlled by the control unit of the burner if necessary The heat exchange surface is made of hi...

Page 6: ...omical and efficient operation of the boiler burner system in the installation Why is regular maintenance important Heating systems should be maintained on a regular basis for the following reasons To...

Page 7: ...aintenance The use of special protec tive equipment safety goggles tightly fitted is recommended CAUTION Periodic cleaning as well as supervision of the burner will prevent any incidents caused by fau...

Page 8: ...from the burner and collect the pellets passed from the conveyor into a bag for 10 min Weigh the pellets passed and multiply by the factor 0 03 The calculated value is the power in KW h Example If th...

Page 9: ...ner settings to use exhaust gas analyser IMPORTANT Default values of the parameters should not be taken for granted The settings must be adjusted individually according to REQUIRED POWER TILT OF THE S...

Page 10: ...user you may only make repairs which involve just a simple replacement of the grate In case of first commissioning of the boiler condensation of water vapour on the heating surfaces of the heat excha...

Page 11: ...stat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of rev...

Page 12: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Page 13: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Page 14: ...14 Mareli Systems WIRING DIAGRAM...

Page 15: ...15 Mareli Systems...

Page 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Reviews: