background image

 

 

 

    

 

 

 

 

 

 

 

 

 

 

 

  

 

Slimline Burner Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

                          www.iconfires.com

 

Summary of Contents for Slimline SB1100C

Page 1: ...Slimline Burner Manual www iconfires com ...

Page 2: ...TO AN AREA WHERE THERE IS A DRAFT WHICH CAN AFFECT THE FLAME NEVER POSITION THE BURNER WITHIN RANGE OF COMBUSTIBLE ITEMS THAT CAN BE MOVED BUMPED BY ACCIDENT OR BLOWN BY THE WIND E G CURTAINS BLANKETS PAPERS ETC ONLY USE THE SLIMLINE BURNER IN AREAS WITH GOOD VENTILATION DO NOT COVER THE SLIMLINE BURNER VENT WITH ANY DECORATIVE ITEMS WHETHER THEY ARE COMBUSTIBLE OR NON COMBUSTIBLE INCLUDING BUT NO...

Page 3: ...t this step as a double motion still applying strong downward force in quick succession Never blow on the flame whilst the Sliding Lid is in an open position If your Slimline Burner does not ignite after it has been closed overnight you will need to refill the Burner to a full level to enable the Burner to be relit VERY IMPORTANT Take special care when adding fuel to the Slimline Burner always clo...

Page 4: ...teps NEVER light the Slimline Burner if it is filled past the filling line by more than 15mm shown in the section of Filling the Slimline Burner Remove the Slimline Burner from its housing using the hooks on the back end of the Sliding Lid Handle or rubber gloves Empty the excess fuel into a container suitable to hold the volume of the Burner Wipe off all excess fuel that may have dripped on the o...

Page 5: ...on Average SB500C 500x100x100 2 75 ℓ Brushed 304 SS up to 90 m 40 m 2 5 kW hr 6 9 hrs 0 30 ℓ hr SB800C 800x100x100 4 50 ℓ Brushed 304 SS up to 165 m 70 m 4 35 kW hr 5 5 8 5 hrs 0 60 ℓ hr SB1100C 1100x125x10 0 6 25 ℓ Brushed 304 SS up to 210 m 90 m 7 25 kW hr 6 5 9 hrs 0 90 ℓ hr SB1400C 1400x125x10 0 8 15 ℓ Brushed 304 SS up to 270 m 110 m 9 5 kW hr 7 9 5 hrs 0 90 ℓ hr Average consumption and burn ...

Page 6: ...re filling lighting and operating Installed in a position that limits relocation requirements to eliminate the risk of accidents caused by fuel spillage These Burners are not designed to be relocated frequently Installed into a level platform Not installed directly beside or near wallpaper laminate veneer or any surface that has not been fire rated and considered combustible A minimum of 1000mm ra...

Page 7: ...t Distance to Non Combustib le Items F Back Distance to Non Combustib le Items G Height Above Cut out to Non Combustib le Items Distance to Combustib le Items E Front Distance to Combustib le Items H Back Distance to Combustib le Items I Height Above Cut out to Combustib le Items SB500C 50 mm 50 mm 50 mm 500 mm 500 mm 500 mm 500 mm 1550 mm SB800C 50 mm 50 mm 50 mm 500 mm 500 mm 500 mm 500 mm 1550 ...

Page 8: ...on Combustible Items F Back Distance to Non Combustible Items G Height Above Cut out to Non Combustible Items Distance to Combustible Items E Front Distance to Combustible Items H Back Distance to Combustible Items I Height Above Cut out to Combustible Items SB500C 50 mm 50 mm 50 mm 500 mm 500 mm 500 mm 500 mm 1550 mm SB800C 50 mm 50 mm 50 mm 500 mm 500 mm 500 mm 500 mm 1550 mm SB1100C 50 mm 50 mm...

Page 9: ...ts in the centre hole of the Vent Plate DO NOT OVERFILL Please wipe any spillage or excess fuel before proceeding to Step 2 2 Igniting the Slimline Burner Seal the fuel canister used to fill the Burner and move to a safe distance away from the Burner While standing at arm s length away from the Burner use a long arm lighter as per the image above to introduce a flame to the openings in the Vent Pl...

Page 10: ...Lid as indicated above Note the flame intensity takes a few minutes to change after an adjustment has been made 4 Extinguishing the Flame Using the Sliding Lid Handle pull the Sliding Lid to the front closed position Should the flame not extinguish with the first try please repeat until extinguished It should be a swift action coupled with downward pressure ...

Page 11: ...t or replace a product where the defect or fault is caused or contributed to by i the failure of the Purchaser to install the product according to specific installation instructions either supplied within each product box or carton or available on the Icon Fires website or through the retailer representative or ii use of the product in a manner or for a purpose for which it was not designed 4 All ...

Page 12: ...12 QC Checklist Components Handles 2 of 500 Burner only 1of Slider 1 of 1400 Burner 2 of Manual 1of Pump 1 of Burner body 1 of Checked by ...

Page 13: ...13 www iconfires com ...

Reviews: