24
Mareli Systems
Description
Code
PRob
Hi
Clean
Port
Ignition
block
Cleaning on
Link Error
Anomaly of the probes checking, during Check Up phase.
Room temperature greater than 99 °C.
This message notifies that the planned hours of functioning (parameter T67) are reached.
Door Open.
The message appears if the system is turned off during Ignition (after Preload) not manually:
the system will stop only when it goes in Run Mode.
Periodical Cleaning in progress.
No communication between motherboard and keyboard
MESSAGES
Exhaust T. [°C]
- Exhaust temperature;
Room T. [°C]
- Room Temperature ; it is displayed only if an input has been set as a Room Probe;
Boiler T.
[°C]
- Boiler Temperature;
Buffer T. [°C]
- Buffer Temperature, it is visible only if P26 is set on 2,3,4;
Pressure [mbar]
- Water pressure;
Air Flux
- Air flow; it is visible only if A24 is different from 5;
Fan Speed [rpm]
- Exhaust fan speed; it is visible only if P25 is different from 0;
Auger [s]
- Auger work time; it is visible only if P81 is equal to 0;
Recipe [nr]
- Combustion recipe set; it is visible only if P04 is greater than 1;
Product Code: 510
- Product code;
VISUALIZATIONS
USER MENU 1
Combustion Management
Power - In this menu is possible to modify the combustion power of the system. It can be set in automatic or
manual modality . In the first case the system chooses the combustion power. In the second case the user selects
the desired power. On the left side of the display are signalled the combustion modality (A=automatic combustion,
M=manual combustion) and the working power of the system.
Recipe - Menu to select the combustion recipe. The maximum value is the number of recipes visible to the user.
Heating Management
Boiler thermostat - Menu to change the value of the boiler thermostat .
Buffer thermostat - Menu to change the value of the Buffer Thermostat; it is only visible if a plumbing plan with a
Buffer is selected.
Room Thermostat - This Menu allows to modify the Local Room Thermostat’s value. It is visible only if the ambient
probe is select.
Summer-Winter - Menu that allows the selection Summer-Winter.
Manual Load
The procedure activates the pellet manual loading with activation in continue modality of the Auger engine. The
loading is stopped automatically after 600 seconds. The system must be OFF for the function can be activated.
Cleaning Reset
Menu to reset the ‘System Maintenance 2’ function.
Summary of Contents for ECOSTAR 12
Page 14: ...14 Mareli Systems CLEANING THE GLASS USE A NON ABRASIVE CLOTH ECOSTAR AUTO...
Page 15: ...15 Mareli Systems CLEANING THE PELLET TANK ECOSTAR AUTO...
Page 18: ...18 Mareli Systems CLEANING THE ASH CONTAINER 1 ECOSTAR AUTO 24 30 35 KW...
Page 19: ...19 Mareli Systems CLEANING THE ASH CONTAINER 2 ECOSTAR AUTO 24 30 35 KW...
Page 20: ...20 Mareli Systems CLEANING THE ASH CONTAINER 3 ECOSTAR AUTO 24 30 35 KW...
Page 21: ...21 Mareli Systems CLEANING THE ASH CONTAINER ECOSTAR AUTO 12 18 KW...
Page 34: ...34 Mareli Systems...
Page 35: ......