23
Mareli Systems
The main frame shows:
time and date, chrono activation, combustion
power and recipe, functioning state, error code,
main temperature, main thermostat,
summer/winter mode.
Button
Function
P1
P2
P3
P4
P5
P6
Exit Menu/Submenu;
Ignition and extinguishing (push for 3 seconds), Reset errors (push for 3 seconds), Enable/disable chrono;
Enter in User Menu 1/submenu, Enter in User Menu 2 (push for 3 seconds), Save data;
Enter in Visualizations Menu, Increase
Activation chrono time band
Enter in Visualizations Menu, Decrease
Led
Function
D1
D9
D2
D10
D3
D11
D4
D12
Igniter ON
Auger ON
Pump 1 ON
V2:
Pump 2 ON
External Chrono reached
Lack of pellet
Local Room Thermostat reached
Sanitary water demand
Er01
- Security Error High Voltage 1. It may also intervene with the system off;
Er02
- Security Error High Voltage 2. It can only intervene if the Combustion fan is active;
Er03
- Extinguishing for low exhaust temperature or missing light in the brazier;
Er04
- Extinguishing for water over temperature;
Er05
- Extinguishing due to high exhaust temperature;
Er06
- Pellet Thermostat open (flame return from the brazier);
Er07
- Encoder Error. The error may occur due to lack signal from Encoder;
Er08
- Encoder Error. The error can occur due to problems of adjustment of the number of revolutions;
Er09
- Water pressure low;
Er10
- Water pressure high;
Er11
- Clock Error. The error occurs due to problems with the internal clock;
Er12
- Extinguishing for ignition failure;
Er15
- Extinguishing due to power failure for more than 50 minutes;
Er16
- RS485 communication error (Display);
Er17
- Adjusting the Air Flow Failed;
Er18
- No more Pellet in the bunker;
Er23
- Boiler probe or Back boiler probe or probe Buffer open;
Er25
- Engine cleaning brazier broken;
Er26
- Engine cleaning broken;
Er27
- Engine cleaning 2 broken;
Er39
- Sensor Flowmeter broken;
Er41
- Minimum air flow in Check Up is not reached;
Er42
- Maximum air flow exceeded;
Er44
- Open door error;
Er47
- Error Encoder Auger: missing signal Encoder;
Er48
- Error Encoder Auger: Auger regulation speed not achieved;
Er52
- Error Module I/O I2C;
Er57
- Test ’Forced Draught High’ in Check Up fail;
Service
- Service error. It notifies that the planned hours of functioning is reached. It is necessary to call for service.
ALARMS
CONTROL PANEL: USE AND FUNCTIONS
Summary of Contents for ECOSTAR 12
Page 14: ...14 Mareli Systems CLEANING THE GLASS USE A NON ABRASIVE CLOTH ECOSTAR AUTO...
Page 15: ...15 Mareli Systems CLEANING THE PELLET TANK ECOSTAR AUTO...
Page 18: ...18 Mareli Systems CLEANING THE ASH CONTAINER 1 ECOSTAR AUTO 24 30 35 KW...
Page 19: ...19 Mareli Systems CLEANING THE ASH CONTAINER 2 ECOSTAR AUTO 24 30 35 KW...
Page 20: ...20 Mareli Systems CLEANING THE ASH CONTAINER 3 ECOSTAR AUTO 24 30 35 KW...
Page 21: ...21 Mareli Systems CLEANING THE ASH CONTAINER ECOSTAR AUTO 12 18 KW...
Page 34: ...34 Mareli Systems...
Page 35: ......