Marecoluce Challenge Solar User Manual Download Page 7

7

STUD

 SOLAR

User's manual

Electronic circuit board (ECB) Stud Solar

Factory standard programming: 
SMART MODE operating mode with on at sunset for 8 hours and a battery duration of 3 nights 
(the luminosity for the grid connection is set at 100% and the time for the movement sensor is set to 2 
minutes.

NORMAL 

In this mode the luminosity of the LEDs is fixed at a constant 50% (175mA). Everything is dependent on the 
panel: if the battery is recharged with the same quantity of energy it consumed the previous night, then the 
system is in energy balance and will guarantee light every night, otherwise, it will use the battery’s energy 
reserve until it runs out (the battery will shut off when only 20% storage remains).
The possible running modes are:
- on at sunset for 8 hours
- on at sunset for 10 hours
- on at sunset for 4 hours, then shutting off internal LED ring and reducing outer ring to 50%, then 2 hours 
before sunrise back to 100%*
- on from sunset to sunrise*

Grid connection: 

the switch over occurs when the battery is no longer capable of supplying the LEDs the 

fixed current (175mA). It is possible to set the dip switch for 100% and if/when the system connects to 
the grid the LEDs run at 100% of their nominal power (350mA). A coloured LED signals that the product is 
connected to the grid.

Movement sensor:

 from sunset to sunrise the system will be on with the outer LED ring running at 50%, until 

the sensor detects movement, from that moment the whole fitting will be on at 50% (NORMAL mode); using 
the dip switches it is possible to select the duration of the increased luminosity: 1,2, or 3 minutes.

SMART 

In this mode the luminosity of the LEDs is variable. Priority is given to battery charge; this calculated each 
night based on the energy transferred from the panel. The energy to be supplied to the LEDs is determined 
based on an algorithm which is divided by the nightly duration and the operating mode (in this case SMART). 
If the panel manages to recharge the battery with the same quantity of energy it consumed the previous night, 
then the system is in energy balance and will guarantee light every night, otherwise, it will use the battery’s 
energy reserve until it runs out (the battery will shut off when only 20% storage remains).
The possible running modes are:
- on at sunset for 8 hours
- on at sunset for 10 hours
- on at sunset for 4 hours, then shutting off internal LED ring and reducing outer ring to 50%, then 2 hours 
before sunrise back to 100%*
- on from sunset to sunrise*

Grid connection: 

the switch over occurs when the battery is no longer capable of running the LEDs at 50% 

luminosity. It is possible to set the dip switch for 100% and if/when the system connects to the grid the LEDs 
run at 100% of their nominal power (350mA). 
A coloured LED signals that the product is connected to the grid. 

Movement sensor: 

from sunset to sunrise the system will be on with the outer LED ring running at 50%, until 

the sensor detects movement, from that moment the whole fitting will be on at full luminosity. Using the dip 
switches it is possible to select the duration of the increased luminosity: 1,2, or 3 minutes.

*The running modes “sunset to sunrise” and “4hrs from sunset – 2hrs from sunrise” will be operative after 
3 days and 3 nights; before this time has passed the system will function for “8hrs from sunset”.

Summary of Contents for Challenge Solar

Page 1: ...lation of the fitting Pag 3 Challenge Solar installation of the fitting Pag 4 Electronic circuit board Deva Solar and Stud Solar Pag 6 Programming Deva Solar Pag 7 Programming Stud Solar Pag 8 Program...

Page 2: ...icollars of the panel Position the panel 3 on the brackets 4 of the pole top and tighten the screws 2 of the semicollars Open the door of the battery box by using the key included Place the battery 6...

Page 3: ...lectrical compartment The sensor must be in clean contact with a supply voltage between 12VDC and 17VDC Untighten the screw 1 Loosen the screw 2 Remove the gear tray cover 3 Insert Stud Solar 1 or Stu...

Page 4: ...X 0 8 Nm 1b 5 7 2 5 Nm 3SX SX DX 2 8 9 8 1 24 24LL 36 2 5 Nm CHALLENGE SOLAR CHALLENGE SOLAR Electronic circuit board pre installed and factory set for programming modes see pag 8 9 10 Installation of...

Page 5: ...G the luminaires 1x60W 2x30W 1x90W have n 2 supply cables connect these two supply cables together first then connect them to the terminal block Position the pole top without the solar panels on the t...

Page 6: ...f the increased luminosity 1 2 or 3 minutes SMART In this mode the luminosity of the LEDs is variable Priority is given to battery charge this calculated each night based on the energy transferred fro...

Page 7: ...the increased luminosity 1 2 or 3 minutes SMART In this mode the luminosity of the LEDs is variable Priority is given to battery charge this calculated each night based on the energy transferred from...

Page 8: ...ation OFF OFF 8 hours OFF ON 10 hours ON OFF 4 hours at sunset and 2 hours before sunrise ON ON from sunset to sunrise Dip 5 LEDs at 100 luminosity if the system connects to the grid OFF Connected ON...

Page 9: ...0 and the time for the movement sensor is set to 2 minutes Dip 1 Battery duration SMART mode OFF 3 nights duration without recharging ON 2 nights duration without recharging Dip 2 Programming mode OFF...

Page 10: ...y has insufficient charge to switch to light up the product the ECB remains in this operating mode up until the end of the pre set light up time which can be set up via dip switch 4 flashes LEDs off a...

Page 11: ...EDs for displaying the state of charge red yellow green1 and green 2 3 Terminal block for connecting the solar panel 4 Terminal block for connecting the battery 5 Terminal block for connection the lum...

Page 12: ...ammed for an 8 hours operation to change the setting follow the instructions of PA RC100 controller The 5 minutes On Off delay has been set to avoid that the luminaires switch on off if the panels are...

Page 13: ...on Check the battery and replace it if necessary Luminaires cannot be operating info LED flashing red green Luminaires output is switched off due to excessive battery voltage The luminaires output aut...

Page 14: ...g should be carried out while panel is cool either in early morning or in late evening Cleaning consists in washing the panels with water and gentle detergents non abrasive by taking care to avoid str...

Page 15: ...lation The product must be installed according to the supplied installation instructions For all the solar luminaires is required a periodical maintenance including the following steps To clean the so...

Page 16: ...47032 Bertinoro FC Italia Via S Croce 121 z i tel 39 0543 4687 fax 39 0543 449051 info marecoluce it marecoluce it...

Reviews: