Marecoluce Challenge Solar User Manual Download Page 12

12

CHALLENGE SOLAR

LED displays

LED

Status

Meaning

Info LED

illuminates green

Normal operation

Flashing  red

Indicates a fault (see "Faults and remedies")

Red LED

Flashing quickly

Battery  state of charge ≥30%  <40%

Flashing 

Activation of deep-discharge protection

state of charge <30%

Yellow LED

Illuminates

Battery state of charge ≥40% <50%

Flashing 

Re-activation level of deep-discharge protection (50%) not 

yet reached.

Battery state of charge ≥40% <50%

1. Green LED

Illuminates

Battery state of charge ≥50% <80%

2. Green LED

Illuminates

Battery state of charge ≥80% <100%

Flashing quickly

Battery state of charge =100%; charge regulation active 

with holding current

Connection

1st step: connect the luminaires.
Connect the L+ (brown) luminaire cable to the correct pole, then connect the L- (blue) luminaire cable to 
the correct pole. In the case of connection of more than one luminaire, conduct parallel connection.
2nd step: connect the battery connections.

Operation

The electronic circuit board immediately begins operation once the battery is connected or the external 
fuse is inserted. The display shows the current operating mode. 
It is factory programmed for an 8 hours operation; to change the setting follow the instructions of PA 
RC100 controller.

The 5 minutes On/Off delay has been set to avoid that the luminaires switch on/off if the  panels  are 
temporarily illuminated/obscured

 

Protection functions

The following integrated protection functions of the electronic circuit board ensure that the  battery is 
handled as gently as possible.
These protection funcions are part of the  basic function of the electronic circuit  board:

• Overcharge protection
• Deep discharge protection
• Battery undervoltage protection
• Solar panel reverse current protection

The following installation faults do not destroy the circuit board. After having corrected the fault, the device 
will continue to operate regularly:

• Protection from solar panel short circuits/incorrect solar panel polarity *
• Protection from short circuits at the luminaires output, or excessive luminaires current
• Protection from battery connection with incorrect polarity
• Protection from solar panel overcurrent
• Protection from luminaires overtemperature
• Protection from overvoltage at the luminaires output

*the reversal -polarity protection of the solar panel in a 24V system is only provided up to an open-circuit 
voltage of  35V.

Electronic circuit board Challenge solar – Operating status LED indicators

User's manual

Summary of Contents for Challenge Solar

Page 1: ...lation of the fitting Pag 3 Challenge Solar installation of the fitting Pag 4 Electronic circuit board Deva Solar and Stud Solar Pag 6 Programming Deva Solar Pag 7 Programming Stud Solar Pag 8 Program...

Page 2: ...icollars of the panel Position the panel 3 on the brackets 4 of the pole top and tighten the screws 2 of the semicollars Open the door of the battery box by using the key included Place the battery 6...

Page 3: ...lectrical compartment The sensor must be in clean contact with a supply voltage between 12VDC and 17VDC Untighten the screw 1 Loosen the screw 2 Remove the gear tray cover 3 Insert Stud Solar 1 or Stu...

Page 4: ...X 0 8 Nm 1b 5 7 2 5 Nm 3SX SX DX 2 8 9 8 1 24 24LL 36 2 5 Nm CHALLENGE SOLAR CHALLENGE SOLAR Electronic circuit board pre installed and factory set for programming modes see pag 8 9 10 Installation of...

Page 5: ...G the luminaires 1x60W 2x30W 1x90W have n 2 supply cables connect these two supply cables together first then connect them to the terminal block Position the pole top without the solar panels on the t...

Page 6: ...f the increased luminosity 1 2 or 3 minutes SMART In this mode the luminosity of the LEDs is variable Priority is given to battery charge this calculated each night based on the energy transferred fro...

Page 7: ...the increased luminosity 1 2 or 3 minutes SMART In this mode the luminosity of the LEDs is variable Priority is given to battery charge this calculated each night based on the energy transferred from...

Page 8: ...ation OFF OFF 8 hours OFF ON 10 hours ON OFF 4 hours at sunset and 2 hours before sunrise ON ON from sunset to sunrise Dip 5 LEDs at 100 luminosity if the system connects to the grid OFF Connected ON...

Page 9: ...0 and the time for the movement sensor is set to 2 minutes Dip 1 Battery duration SMART mode OFF 3 nights duration without recharging ON 2 nights duration without recharging Dip 2 Programming mode OFF...

Page 10: ...y has insufficient charge to switch to light up the product the ECB remains in this operating mode up until the end of the pre set light up time which can be set up via dip switch 4 flashes LEDs off a...

Page 11: ...EDs for displaying the state of charge red yellow green1 and green 2 3 Terminal block for connecting the solar panel 4 Terminal block for connecting the battery 5 Terminal block for connection the lum...

Page 12: ...ammed for an 8 hours operation to change the setting follow the instructions of PA RC100 controller The 5 minutes On Off delay has been set to avoid that the luminaires switch on off if the panels are...

Page 13: ...on Check the battery and replace it if necessary Luminaires cannot be operating info LED flashing red green Luminaires output is switched off due to excessive battery voltage The luminaires output aut...

Page 14: ...g should be carried out while panel is cool either in early morning or in late evening Cleaning consists in washing the panels with water and gentle detergents non abrasive by taking care to avoid str...

Page 15: ...lation The product must be installed according to the supplied installation instructions For all the solar luminaires is required a periodical maintenance including the following steps To clean the so...

Page 16: ...47032 Bertinoro FC Italia Via S Croce 121 z i tel 39 0543 4687 fax 39 0543 449051 info marecoluce it marecoluce it...

Reviews: