![Marecoluce Challenge Solar User Manual Download Page 2](http://html1.mh-extra.com/html/marecoluce/challenge-solar/challenge-solar_user-manual_1726880002.webp)
2
(2)
(3)
(4)
(6)
(1)
Ø102mm
(5)
1
2
3
2.5 Nm
2.5 Nm
2.5 Nm
DEVA SOLAR
DEV
A SOLAR
*Grid connection: Pag.6
Electronic circuit board pre-installed
and factory set (for programming
modes see pag.6-7)
To facilitate the installation Mareco Luce recommends to
connect the luminaire and the pole-top to the pole first, and then
to fix the pole to the ground.
Untighten the screws
(5)
of the semicollar. Insert the cable
through the hole in the pole and let it comes out from the
top of the pole (in case the pole is not provided by Mareco
Luce confirm to the manufacturer the technical specifications
required).Position the luminaire at a height of 6,5mts (ground
height).Tighten the screws
(5)
of the semicollar. Max screwer
strength 2.5Nm
Position the pole top without the solar panel on the top of the
pole.Orient the pole top with respect to the sun.
Insert the cable of the luminaire into the battery box previousely
positioned. Secure the pole top to the pole by tightening the
screws
(1)
, once the pole top is oriented with respect to the sun.
Loosen the screws
(2)
of the semicollars of the panel.
Position the panel
(3)
on the brackets
(4)
of the pole top, and
tighten the screws
(2)
of the semicollars.
Open the door of the battery box by using the key (included).
Place the battery
(6)
inside the battery box paying attention to
position it correctly on the brackets.
Close the door of the battery box by using the key (included)
Connecting process of the luminaire
Tighten the 4 poles cable of the luminaire to the M16 cable
gland and connect it as follows:
Clamp mark L1 + cable red/white
Clamp mark L1 - cable green/white
Clamp mark L2 + cable white
Clamp mark L2 - cable blue/white
Connecting process to the grid (if present)
Tighten the mains cable coming from the pole to the M20 cable
gland, and connect it as follows:
Clamp mark F phase wire
Clamp mark N neutral wire
Clamp mark T ground cable
Connect all the cables, then tighten the cable glands, and
eventually close the grey watertight box placed inside the
battery box
Movement sensor: Deva Solar 16W is pre-set for the connection
of the remote sensor through a terminal block placed inside the
electrical compartment. The sensor must be in "clean contact"
with a supply voltage between 12VDC and 17VDC
Installation of the fitting
*Led position in case of
grid connection
User's manual