TABLE 12-5: RESISTANCE VALUES - MAIN WINDINGS
NOMINAL COLD (25°C) RESISTANCE IN OHMS
Base Model
Low Voltage
Winding
H-SG-
Main
Stator
Main
Rotor
431RSL2004
431RSL2006
431RSL2008
432RSL2010
430011
430012
430013
430014
.1160
.0898
.0685
.0534
.139
.149
.160
.170
432RSL2012
432RSL2014
432RSL2016
432RSL2018
430018
430015
430017
430016
.0389
.0353
.0245
.0228
.186
.189
.225
.226
433RSL2023
433RSL2027
430042
430039
.0144
.0137
.286
.297
571RSL2020
571RSL2024
571RSL2028
570020
570021
570022
.0316
.0253
.0214
.306
.322
.328
572RSL2032
572RSL2037
572RSL2040
572RSL2045
570023
570024
570025
270026
.0159
.0144
.0109
.0092
.363
.374
.402
.419
573RSL2048
573RSL2052
573RSL2056
570027
570028
570029
.0082
.0068
.0054
.457
.490
.542
741RSL2060
741RSL2064
741RSL2068
741RSL2072
740021
740022
740023
740024
.0061
.0046
.0042
.0037
.609
.647
.679
.718
742RSL2076
740025
.0032
.750
744RSL2284
744RSL2288
740026
740027
.0026
.0018
.892
1.044
Base Model
Medium Voltage
Winding
H-SG-
Main
Stator
Main
Rotor
573FSM2328
573FSM2336
570201
570202
1.249
.837
.383
.424
574FSM2340
574FSM2348
574FSM2352
570203
570204
570205
.694
.526
.410
.458
.498
.553
741FSM2360
741FSM2364
741FSM2368
740201
740202
740203
.462
.380
.297
.609
.662
.694
742FSM2372
742FSM2376
742FSM2380
740204
740205
740206
.223
.185
.151
.768
.825
.888
743FSM2384
743FSM2388
740207
740208
.127
.101
.954
1.053
Main stator values shown are line to line on the high wye connection. For low wye connection
divide value shown in table by 4.