TABLE 12-1: MAGNA MAX - FASTENER AND TORQUE SPECIFICATIONS
Part
Description
Fastener Spec.
430-570 Frames
740 Frames
Size Dia.-
Thread
Torque Ft-Lb.
Size Dia.-
Thread
Torque
Ft-Lb.
Front Bracket
Grade 5 cap screws with
flat and lock washers
3/8 - 16
25
1/2 - 13
60
Bearing Caps
Grade 5 cap screws with
lock washers
3/8 - 16
25
3/8 - 16
25
Drive Disc
Grade 8 cap screws with
hardened washers
5/8 - 18
192
5/8 - 18
192
Adapter
(or rear
bracket)
Grade 5 cap screws with
flat and lock washers
3/8 - 16
25
1/2-13
60
Conduit Box
Grade 5 cap screw with
star type lock washer
3/8 - 16
25
1/2-13
60
PMG Stator
Grade 5 cap screws with
Belleville washers
1/2-13
4
1/2-13
4
Exciter Stator
Grade 5 cap screws with
Belleville washers
1/2-13
60
1/2-13
60
Exciter
Armature
(rotor)
Grade 8 cap screw with
Belleville washer
1/2-13
84
1/2-13
84
Cooling Fan
Grade 5 cap screws with
Belleville washers
1/2-13
60
1/2-13
60
Main Rotor
Coil Supports
Grade 8 cap screws with
Belleville washers
5/16-18
19
3/8 - 16
35
Rectifier
Assembly
Mounting
Grade 5 cap screws
1/4-20
4
1/4-20
4
Drive Hub Set
Screw
Socket head set screw 1/4
in. hex key
1/2-13
50
1/2-13
50
NOTES: For table 12-1
All fasteners are SAE (American) standard.
All torque values are for plated hardware that is standard on the MagnaMAX.
If hardware is replaced with non-plated, refer to Table 12-2.
Always use quality hardware of the grade specified.
Main Rotor Coil Supports 570 and 740 frame only. Not used on 430 frames.