Low Pass Filter
: from this sub-frame it is possible to set the Output Channels Low Pass Filter
(LPF).
“
Frequency
”: (High Cut frequency) the selectable frequencies range is from 20Hz to 20kHz in
steps of 1/24 of an Octave.
“
Slope
”: allows you to select the X-Over's Low Pass Filter Shape and Order.
The available shapes and orders for the Low Pass Filter are listed below:
–
Bypass
(High Pass Filter Bypassed)
–
Buttw 6dB
(Butterworth Filter 6dB/Oct Slope)
–
Buttw 12dB
(Butterworth Filter 12dB/Oct Slope)
–
LRiley 12dB
(Linkwitz/Riley Filter 12dB/Oct Slope)
–
Bessel 12dB
(Bessel Filter 12dB/Oct Slope)
–
Buttw 18dB
(Butterworth Filter 18dB/Oct Slope)
–
Buttw 24dB
(Butterworth Filter 24dB/Oct Slope)
–
LRiley 24dB
(Linkwitz/Riley Filter 24dB/Oct Slope)
–
Bessel 24dB
(Bessel Filter 24dB/Oct Slope)
EQ:
from this sub-frame it is possible to set the Output Channels five available Peaker (Bell) or
variable Q Shelving Filters.
The DPA880 allows the user to select either Bell or variable Q Shelving Parameters and assign
them independently using the 5 available filters.
The selection can be done just pressing the “Peak Eq” button on top of the filters' gain sliders and
selecting one of the 3 available filters' type: Peaker, variable Q high Shelving and variable Q low
Shelving.
BELL Filter:
here Center Frequency, Band Width (Q) and Gain can be adjusted.
“
Center Frequency
”: the selectable frequencies range is from 20Hz to 20kHz in steps of 1/24 of
an Octave.
“
Bandwidth BW
”: the selectable BW range is from 0.0312 Octave (Q=10) up to 3.59 Octave
(Q=0.4) in steps of 0.1 Q.
“
Gain
”: the selectable Gain range is from -12dB to +12dB in steps of 0.5 dB.
Variable Q Low Shelving Filter:
here Center Frequency, Band Width (Q) (Slope) and Gain can
be adjusted.
“
Center Frequency
”: the selectable frequencies range is from 20Hz to 20kHz in steps of 1/24 of
an Octave.
“
Bandwidth BW (Slope)
”: the selectable BW range is from 0.0312 Octave (Q=10) up to 3.59
Octave (Q=0.4) in steps of 0.1 Q.
“
Gain
”: the selectable Gain range is from -12dB to +12dB in steps of 0.5 dB.
Variable Q High Shelving Filter:
here Center Frequency, Band Width (Q) (Slope) and Gain can
be adjusted.
“
Center Frequency
”: the selectable frequencies range is from 20Hz to 20kHz in steps of 1/24 of
an Octave.
“
Bandwidth BW (Slope)
”: the selectable BW range is from 0.0312 Octave (Q=10) up to 3.59
Octave (Q=0.4) in steps of 0.1 Q.
“
Gain
”: the selectable Gain range is from -12dB to +12dB in steps of 0.5 dB.
Note
: each single filter can be independently “bypassed” for an easy setting/use of them.
To “Bypass” the single filter, just press the “Bypass” button below the filter’s parameters.