MENU
“1/2/3/4/5/6
Output
Channels
Editing
” [
Access
by
pushing
the
“1/2/3/4/5/6”
buttons
]
NAV
/
PAR
1
Encoder
NAV
/
PAR
1
Enc
.
PM
2
Enc
.
PM
3
Enc
.
[
to
navigate
between
menus
]
[
to
chose
values
for
the
parameters
,
no
need
to
confirm
the
chosen
values
,
which
are
automatically
loaded
during
the
encoders
use
]
1.
Output
[
x
] [
Name
]
HPF
20.0
Hz
No
Cut
-
Off
-> 20.0
Hz
No
Cut
-
Off
PAR
1
N
/
A
[
Freq
.] 20
Hz
[
Type
/
Slope
]
No
Cut
-
Off
: :
20
kHz
Bessel
24
dB
/
Oct
2.
Output
[
x
] [
Name
]
LPF
20.0
Hz
No
Cut
-
Off
-> 20.0
Hz
No
Cut
-
Off
PAR
1
N
/
A
[
Freq
.] 20
Hz
[
Type
/
Slope
]
No
Cut
-
Off
: :
20
kHz
Bessel
24
dB
/
Oct
3.
Output
[
x
] [
Name
]
PEQ
/
SHV
- 1/7
1.00
kHz
BW
/
SHV
_
Slope
=1.00/
up
to
-12
dB
+ 0.0
dB
(
when
the
filter
'
s
gain
= 0.0
dB
ONLY
,
through
the
PM
2
it
is
possible
to
chose
and
select
between
a
Bell
or
a
Shelving
filter
)
If
through
the
PM
2,
being
the
filter
'
s
gain
= 0.0
dB
,
has
been
selected
a
Bell
filter
,
just
defining
its
Bandwidth
BW
to
be
greater
then
0,
then
the
Bell
filters
can
be
set
by
the
following
parameters
3.1
Output
[
x
]
[
Name
]
EQ
-
X
(
up
to
7
filters
available
)
-> 1.00
kHz
BW
=1.00 +0.0
dB
[
Freq
.] 20
Hz
[
BW
] 0.05
[
Amp
.] -15.0
dB
:
: :
20
kHz
3.00 +15.0
dB
If
through
the
PM
2,
being
the
filter
'
s
gain
= 0.0
dB
,
has
been
selected
a
Low
Shelving
filter
,
just
defining
its
Slope
(1
st
or
2
nd
order
available
, -6
dB
or
-12
dB
),
then
the
Low
Shelving
filter
can
be
set
by
the
following
parameters
3.2
Output
[
x
]
[
Name
]
EQ
-
X
(
up
to
7
filters
available
)
-> 1.00
kHz
(-6/-12)
LoSh
+0.0
dB
[
Freq
.]
20
Hz
PM
2
N
/
A
[
Amp
.]
-15.0
dB
:
:
20
kHz
+15.0
dB
If
through
the
PM
2,
being
the
filter
'
s
gain
= 0.0
dB
,
has
been
selected
a
High
Shelving
filter
,
just
defining
its
Slope
(1
st
or
2
nd
order
available
, -6
dB
or
-12
dB
),
then
the
High
Shelving
filter
can
be
set
by
the
following
parameters
3.3
Output
[
x
]
[
Name
]
EQ
-
X
(
up
to
7
filters
available
)
-> 1.00
kHz
(-6/-12)
HiSh
+0.0
dB
[
Freq
.] 20
Hz
PM
2
N
/
A
[
Amp
.] -15.0
dB
:
:
20
kHz
+15.0
dB
4.
Output
[
x
] [
Name
]
Vu
-
Meter
Vu
-
Meter
=
Level
->
Vu
-
Meter
=
Level
PAR
1
N
/
A
Level
Same
as
PAR
2
Limiter
Act
.
5.
Output
[
x
] [
Name
]
Name
Name
= [
Name
]
->
Name
= _
(
For
Editing
the
Device
'
s
Name
,
refer
to
the
Details
on
the
“
Utility
Menus
Use
”
Section
)
ENTER
ESC
ENTER
ESC
ENTER
ESC
ENTER
ESC
ENTER
ESC
7
Summary of Contents for DPA-260A
Page 1: ...19 482mm DIGITAL USB ...
Page 2: ...1 36 DPA 260A Speaker Management DPA 260A Connection Page37 ...