The
available
shapes
and
orders
for
the
High
Pass
Filter
,
that
are
accessible
by
rotating
the
“
PM
3”
encoder
,
are
listed
below
:
–
No
Cut
-
Off
(
High
Pass
Filter
Bypassed
)
–
Butwrth
6
dB
(
Butterworth
Filter
6
dB
/
Oct
Slope
)
–
Butwrth
12
dB
(
Butterworth
Filter
12
dB
/
Oct
Slope
)
–
Lnk
/
Ril
12
dB
(
Linkwitz
/
Riley
Filter
12
dB
/
Oct
Slope
)
–
Bessel
12
dB
(
Bessel
Filter
12
dB
/
Oct
Slope
)
–
Butwrth
18
dB
(
Butterworth
Filter
18
dB
/
Oct
Slope
)
–
Butwrth
24
dB
(
Butterworth
Filter
24
dB
/
Oct
Slope
)
–
Lnk
/
Ril
24
dB
(
Linkwitz
/
Riley
Filter
24
dB
/
Oct
Slope
)
–
Bessel
24
dB
(
Bessel
Filter
24
dB
/
Oct
Slope
)
Note
1 :
once
the
desired
options
have
been
selected
using
the
2
encoders
,
they
are
automatically
saved
as
current
and
stored
in
the
DPA-260A
system
status
once
leaving
the
page
.
Note
2 :
to
exit
this
page
,
push
the
“
ESC
”
button
.
LPF
sub
-
menu
–
from
this
sub
-
menu
it
is
possible
to
set
the
Output
Channels
Low
Pass
Filter
(
LPF
).
The
following
is
an
example
of
a
LPF
sub
-
menu
screen
with
the
filter
set
at
24
dB
Linkwitz
/
Riley
on
Output
1...
using
the
name
“
Low
” (
see
later
for
assigning
a
Name
to
the
outputs
):
The
filter
'
s
parameters
can
be
modified
by
use
the
“
PM
2”
and
“
PM
3”
encoders
for
editing
the
Filter
'
s
High
Cut
Frequency
and
the
Filter
'
s
Type
and
Order
.
The
High
Cut
Frequency
of
the
Low
Pass
Filter
can
be
edited
using
the
“
PM
2”
encoder
and
the
Filter
'
s
Type
and
Order
can
be
edited
by
using
the
“
PM
3”
encoder
.
“
High
Cut
Frequency
”:
the
selectable
frequencies
range
is
from
20
Hz
to
20
kHz
in
steps
of
1/24
of
an
Octave
and
can
be
adjusted
by
rotating
the
“
PM
2”
encoder
.
“
Low
Pass
Type
and
Order
”:
this
page
allows
you
to
select
the
X
-
Over
'
s
Low
Pass
Filter
Shape
and
Order
.
The
available
shapes
and
orders
for
the
Low
Pass
Filter
that
are
accessible
by
rotating
the
“
PM
3”
encoder
are
listed
below
:
–
No
Cut
-
Off
(
Low
Pass
Filter
Bypassed
)
–
Butwrth
6
dB
(
Butterworth
Filter
6
dB
/
Oct
Slope
)
–
Butwrth
12
dB
(
Butterworth
Filter
12
dB
/
Oct
Slope
)
–
Lnk
/
Ril
12
dB
(
Linkwitz
/
Riley
Filter
12
dB
/
Oct
Slope
)
–
Bessel
12
dB
(
Bessel
Filter
12
dB
/
Oct
Slope
)
–
Butwrth
18
dB
(
Butterworth
Filter
18
dB
/
Oct
Slope
)
–
Butwrth
24
dB
(
Butterworth
Filter
24
dB
/
Oct
Slope
)
–
Lnk
/
Ril
24
dB
(
Linkwitz
/
Riley
Filter
24
dB
/
Oct
Slope
)
–
Bessel
24
dB
(
Bessel
Filter
24
dB
/
Oct
Slope
)
Note
1 :
once
the
desired
options
have
been
selected
using
the
2
encoders
,
they
are
automatically
saved
as
current
and
stored
in
the
DPA-260A
system
status
once
leaving
the
page
.
Note
2 :
to
exit
this
page
,
push
the
“
ESC
”
button
.
Out
-1
Low
LPF
-> 20.0
Hz
Lnk
/
Ril
24
dB
25