Installation of OITs

CE  Com pli ance

The Silver Plus Series OITs have been tested to conform to European CE requirements per
Council Directive 89/336/EEC.  The European Union created these requirements to ensure
conformity among products traded in those countries.  Specifically, the Silver Plus Series
OITs meet or exceed the noise emissions and immunity requirements as set forth in the
EN50081 (Emissions) and EN50082 (Immunity) standards.  These products are designed to
withstand electrical noise in harsh industrial environments.  They also conform to
requirements that limit electrical emissions.  However, this does not guarantee that the
products will be totally immune from possible malfunction in cases where severe electrical
noise occurs.  Therefore, we strongly recommend that you follow the guidelines outlined in
this chapter for proper wire routing and grounding to insure the proper operation of the Silver 
Plus Series OIT.

NEMA Rat ing

The Silver Plus Series OITs are rated for NEMA 4/12 (indoor) or IP65 installations.  This
means that when the OIT is properly mounted to a panel or other enclosure, the front
enclosure of the OIT will provide protection to the inside of the panel from splashing water,
wind blown dust, rain, or hose-directed water.  The OIT must be installed according to the
instructions in this manual to be properly sealed.

En vi ron men tal  Con sid er ations

The Silver Plus Series  is designed to operate in temperatures from 0-45° C.  It is intended for
indoor installations and not designed for outdoor applications.  Avoid installing the Silver
Plus Series  in environments with severe mechanical vibration or shocks.  Do not install the
OIT in enclosures with rapid temperature variations or high humidity.  Either will cause
condensation of water inside the device and eventual damage to the OIT.

Safety  Pre cau tions

Please observe the following precautions when installing the Silver Plus Series  OIT.  Failure 
to comply with these restrictions could result in loss of life, serious personal injury, or
equipment damage.

Warning: 

 Do not operate the OIT in areas subject to explosion due to flammable gases,

vapors, or dusts.

Warning:

  Do not connect the OIT to an AC power source.  You will cause permanent

damage to the OIT.

4

Sil ver Plus Se ries

1010-1006, Rev 01

Summary of Contents for HMI5056T

Page 1: ...Installation Guide 808 134th Street SW Suite 120 u Everett WA 98204u 425 745 3229 www maplesystems com umaple maple systems com 1010 1006 Rev 01 ...

Page 2: ...h the carrier Save the shipping container and packing material in case the equipment needs to be stored returned to Maple Systems or transported for any reason Warranty Maple Systems warrants each product to be free from electrical and mechanical defects in materials and workmanship for a period of two years from the date of shipment This warranty does not apply to defects in the Products caused b...

Page 3: ...Installation Guide 3 1010 1006 Rev 01 ...

Page 4: ...ns that when the OIT is properly mounted to a panel or other enclosure the front enclosure of the OIT will provide protection to the inside of the panel from splashing water wind blown dust rain or hose directed water The OIT must be installed according to the instructions in this manual to be properly sealed Environmental Considerations The Silver Plus Series is designed to operate in temperature...

Page 5: ...se good grounding procedures during installation sporadic malfunction of the OIT may occur Connect the OIT s chassis ground terminal to a reliable earth ground with a low resistance path Route all earth ground wires that lead from the OIT the PLC the power supply and the line filter to a central earth ground point such as a barrier strip This will ensure that no ground current from one device infl...

Page 6: ...rth ground If the control panel is metal make sure it is properly grounded Then connect a short heavy gauge wire 18 AWG from the chassis ground terminal of the OIT to a mounting bolt on the control panel door The mounting bolt must have good electrical contact to the control panel scrape away any paint that may be covering the panel to provide a good connection If the control panel is made of a no...

Page 7: ...T power supply to power switching relays solenoids or other active devices Cable Routing Noise Immunity Follow these guidelines when routing cable to the OIT Always route the OIT communication cable and the power cable away from any AC voltage or rapidly switching DC control lines Never bundle the OIT cables together with 120VAC power wires or with relay wiring Try to keep at least 8 inches 20 cm ...

Page 8: ... back to the signal return of the power supply Do not use the chassis ground wire as your signal return 4To connect the OIT to power 1 Connect the power cable to the OIT a Strip the power cable shield to expose 2 of the black and red wires b Strip about of insulation from the black and red wires c Thread the black and red wires through the ferrite core The shield wire must be outside d Connect the...

Page 9: ...clamps and not form a seal with the gasket The area of the panel or mounting surface where the gasket comes into contact must be flat and free of scratches pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be required Warning The OIT requires a stiff flat smooth...

Page 10: ...eyond snugness or you may damage the housing REINSTALLATION Because the gasket will take a set to the panel be sure to reinstall the OIT to the same panel cutout when a NEMA 4 seal is required For best results also replace the gasket itself 10 Silver Plus Series 1010 1006 Rev 01 Screw clamp locking tabs go through the slots Tighten all screw clamps until they are uniformly snug Ends of screws must...

Page 11: ... switch or router between the PC and the OIT use a straight through or crossover cable as required by the switch or router If an Ethernet port is not available on the PC you may be able to install a USB Ethernet adapter You can also transfer the project to the OIT with a Compact Flash or USB memory device For More Information For information on PLC connection programming and operations of your Sil...

Page 12: ...12 Silver Plus Series 1010 1006 Rev 01 ...

Page 13: ...Installation Guide 13 1010 1006 Rev 01 ...

Page 14: ...14 Silver Series Plus 1010 1006 Rev 01 ...

Page 15: ...Installation Guide 15 1010 1006 Rev 01 ...

Page 16: ...16 Silver Series Plus 1010 1006 Rev 01 ...

Reviews: