Panel Preparation

To provide a NEMA 4 seal, a metal panel or mounting surface that does 
not flex more than 0.010” is required. Thin panels or surfaces may bow 
between the mounting clamps and not form a seal with the gasket.

Allow enough clearance around the unit for the mounting hardware and 
cable connections. Cutout dimensions for each particular HMI model are 
available for print and download from the Support Center-Dimensional 
Drawings section of the Maple Systems website.

The area of the panel or mounting surface where the gasket comes into 
contact must be flat and free of scratches, pits, and other features that 
prevent the gasket from sealing properly. If the panel or mounting 
surface is not uniform, thick, flat, stiff, or smooth enough, then a sealant 
such as silicone may be required.

Note:

  Clean and deburr the panel cutout before the HMI is installed.

Mount the HMI to the Panel

Note:

 The clamps for some models may be slightly different than 

shown here, but operate essentially the same way.

Steps:

1. Prepare the clamps for the HMI by inserting the screws into the 

clamp as shown above. Position the screws so that the ends don’t 
protrude past the clamp edge.

2. Set the HMI in the panel cutout and hold it in place until all clamps 

are in position.

3. Tighten the screw clamps in an even pattern until the unit is secure. 

Recommended torque: 

3.5 in/lbs

Caution:

  Do not over-tighten the screws; the overlay may warp 

or the housing may get damaged.

Summary of Contents for HMI5000L Series

Page 1: ...touchscreens are configured using the EasyBuilder Pro Software For information on programming and configuring the HMI please refer to the EasyBuilder Pro Programming Manual available for free downloa...

Page 2: ...l material in the container against the packing list Maple Systems will not accept responsibility for shortages against the packing list unless notified within 30 days The equipment and accessories we...

Page 3: ...liance The HMIs have been tested to conform to European CE requirements which meet or exceed the noise emissions and immunity requirements as set forth in the EN55022 Emissions and EN55024 Immunity st...

Page 4: ...tional electrical standards when installing the HMI Failure to comply with these restrictions could result in loss of life serious personal injury or equipment damage Warning Do not connect the HMI to...

Page 5: ...wer Supply Selection The power supply used to power the HMI should provide an output of at least 24 VDC 20 measured at the HMI power connector HMI5043DL should be powered with 10 5 28VDC only A DC reg...

Page 6: ...und strap Quiet ground isolated AC Power Line Filter HMI Power Supply Shielded power cable Control panel is tied to a reliable earth ground 2 1 3 4 5 rear side HMI5100L 1 rear side HMI5070L 2 2 3 1 Al...

Page 7: ...round Note If the control panel is made of a non conductive material it is essential that the chassis ground terminal of the HMI is connected to a clean earth ground point located close to the panel C...

Page 8: ...the power cable from the HMI to the power supply The power cable should not be any longer than necessary 2 Install the cable wires referencing the chart below with colors shown for Maple Systems Cable...

Page 9: ...es pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be requir...

Page 10: ...cluded with the EasyBuilder Pro software must be installed when downloading from the PC to the HMI via USB connection Caution When connecting two powered devices via USB a difference in potential can...

Page 11: ...arrow icon located in the lower right corner of the screen 3 Click the gear icon to enter the system settings menu 4 When prompted enter the system password default 111111 5 Navigate to the Network ta...

Page 12: ...EN Hide System Toolbar OPEN OPEN SHORT OPEN Boot Loader mode OPEN OPEN OPEN SHORT Reserved OPEN OPEN OPEN OPEN Normal operation Note Place a jumper cap between the respective header pins to set the ju...

Page 13: ...up remove power An internal fuse except 4 3 display models will prevent damage if the polarity of the DC power is incorrect Check wiring to ensure proper connections and try to power up again USB Sti...

Page 14: ...2 wire 1 RX DATA 2 RX DATA 3 TX 4 TX 5 GND 6 TXD 7 DATA 8 DATA 9 RXD Pin COM1 232 RS 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 HMI XL 5150 DE9S DE9P HMI5100L HMI HMI LB 5070L 5070 HMI XL 5121 Pin COM1 48...

Page 15: ...485 4W RS COM2 COM3 485 2W RS RS 485 4W COM3 1 DATA RX 2 DATA RX 3 TX 4 TX 5 GND 6 DATA RX 7 DATA TX 8 DATA TX 9 DATA RX Pin COM1 RS 232 232 RS COM3 1 2 RXD 3 TXD 4 5 GND 6 7 RTS TXD 8 CTS RXD 9 GND P...

Page 16: ...Enter the desired IP address or select Obtain an IP Address Automatically to enable DHCP 4 Navigate to the LAN2 tab 5 Enter the desired IP address or select Obtain an IP Address Automatically to enab...

Page 17: ...n addition to the standard RJ45 Ethernet port Supported Wi Fi modes are IEEE 802 11 b g n with WPA PSK WPA2 PSK encryption Wi Fi is off by default To enable and configure Wi Fi 1 Enter the System Sett...

Page 18: ...10 Tap Close to exit the Wi Fi setting window 11 Click Apply to save the changes and OK to exit the system settings menu 12 The updated IP addressing will appear in the Wi Fi tabs of the System Inform...

Page 19: ......

Page 20: ...12 www maplesystems com 2019 Maple Systems Inc All rights reserved Maple Systems Inc 808 134th Street SW Suite 120 Everett WA 98204 7333 Phone 425 745 3229 Email support maplesystems com Web www mapl...

Reviews: