background image

2

                             HMI5000L Installation Guide

1010-1018 Rev 12                                                                         www.maplesystems.com

Static Awareness

Do NOT remove the rear cover of the HMI5000L Series product – doing 
so will void the warranty. When the rear cover is removed the circuitry 
inside is exposed to possible damage by electrostatic discharge during 
handling.

Minimize the possibility of any electrostatic discharge by:

Handling the HMI at a static-free, grounded workstation.

Discharging personal static by grounding yourself prior to 
handling the HMI.

Connecting the chassis ground (FG or 

) connector of the HMI 

to a clean earth ground.

Placing the HMI in an antistatic bag during transport.

Unpacking the Unit

Carefully unpack the HMI. Check all material in the container against the 
packing list. Maple Systems will not accept responsibility for shortages 
against the packing list unless notified within 30 days. The equipment 
and accessories were inspected and tested by Maple Systems before 
shipment. Examine the equipment carefully; if any shipping damage is 
evident, notify the carrier immediately. Maple Systems is not responsible 
for claim negotiations with the carrier. Save the shipping container and 
packing material in case the equipment needs to be stored, returned to 
Maple Systems, or transported for any reason.

Packing List

HMI5000L Series Touchscreen
Power Connector
Mounting Clamp Kit
HMI5000L Series Installation Guide
USB Stick Clamp and Spare Fuse Kit (Not on all models)

Warranty

A copy of the Warranty and Limitation of Liability is contained in the 
product box. It can also be found on the Maple Systems website.

Summary of Contents for HMI5000L Series

Page 1: ...touchscreens are configured using the EasyBuilder Pro Software For information on programming and configuring the HMI please refer to the EasyBuilder Pro Programming Manual available for free downloa...

Page 2: ...l material in the container against the packing list Maple Systems will not accept responsibility for shortages against the packing list unless notified within 30 days The equipment and accessories we...

Page 3: ...liance The HMIs have been tested to conform to European CE requirements which meet or exceed the noise emissions and immunity requirements as set forth in the EN55022 Emissions and EN55024 Immunity st...

Page 4: ...tional electrical standards when installing the HMI Failure to comply with these restrictions could result in loss of life serious personal injury or equipment damage Warning Do not connect the HMI to...

Page 5: ...wer Supply Selection The power supply used to power the HMI should provide an output of at least 24 VDC 20 measured at the HMI power connector HMI5043DL should be powered with 10 5 28VDC only A DC reg...

Page 6: ...und strap Quiet ground isolated AC Power Line Filter HMI Power Supply Shielded power cable Control panel is tied to a reliable earth ground 2 1 3 4 5 rear side HMI5100L 1 rear side HMI5070L 2 2 3 1 Al...

Page 7: ...round Note If the control panel is made of a non conductive material it is essential that the chassis ground terminal of the HMI is connected to a clean earth ground point located close to the panel C...

Page 8: ...the power cable from the HMI to the power supply The power cable should not be any longer than necessary 2 Install the cable wires referencing the chart below with colors shown for Maple Systems Cable...

Page 9: ...es pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be requir...

Page 10: ...cluded with the EasyBuilder Pro software must be installed when downloading from the PC to the HMI via USB connection Caution When connecting two powered devices via USB a difference in potential can...

Page 11: ...arrow icon located in the lower right corner of the screen 3 Click the gear icon to enter the system settings menu 4 When prompted enter the system password default 111111 5 Navigate to the Network ta...

Page 12: ...EN Hide System Toolbar OPEN OPEN SHORT OPEN Boot Loader mode OPEN OPEN OPEN SHORT Reserved OPEN OPEN OPEN OPEN Normal operation Note Place a jumper cap between the respective header pins to set the ju...

Page 13: ...up remove power An internal fuse except 4 3 display models will prevent damage if the polarity of the DC power is incorrect Check wiring to ensure proper connections and try to power up again USB Sti...

Page 14: ...2 wire 1 RX DATA 2 RX DATA 3 TX 4 TX 5 GND 6 TXD 7 DATA 8 DATA 9 RXD Pin COM1 232 RS 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 HMI XL 5150 DE9S DE9P HMI5100L HMI HMI LB 5070L 5070 HMI XL 5121 Pin COM1 48...

Page 15: ...485 4W RS COM2 COM3 485 2W RS RS 485 4W COM3 1 DATA RX 2 DATA RX 3 TX 4 TX 5 GND 6 DATA RX 7 DATA TX 8 DATA TX 9 DATA RX Pin COM1 RS 232 232 RS COM3 1 2 RXD 3 TXD 4 5 GND 6 7 RTS TXD 8 CTS RXD 9 GND P...

Page 16: ...Enter the desired IP address or select Obtain an IP Address Automatically to enable DHCP 4 Navigate to the LAN2 tab 5 Enter the desired IP address or select Obtain an IP Address Automatically to enab...

Page 17: ...n addition to the standard RJ45 Ethernet port Supported Wi Fi modes are IEEE 802 11 b g n with WPA PSK WPA2 PSK encryption Wi Fi is off by default To enable and configure Wi Fi 1 Enter the System Sett...

Page 18: ...10 Tap Close to exit the Wi Fi setting window 11 Click Apply to save the changes and OK to exit the system settings menu 12 The updated IP addressing will appear in the Wi Fi tabs of the System Inform...

Page 19: ......

Page 20: ...12 www maplesystems com 2019 Maple Systems Inc All rights reserved Maple Systems Inc 808 134th Street SW Suite 120 Everett WA 98204 7333 Phone 425 745 3229 Email support maplesystems com Web www mapl...

Reviews: