A ticket number (Log Number) will be printed on each ticket and will be incremented after printing each ticket
pair.
We want the printed output to look like:
Mantracourt Electronics Ltd
Ticket No: 0007
Weighment: 12.3456 Kg
Mantracourt Electronics Ltd
Ticket No: 0007
Weighment: 12.3456 Kg
Parameter settings:
Line1=<1B><63><00>Mantracourt Electronics Ltd<0A>
Line2=Ticket No: <LOG><0A>
Line3=Weighment: <TV> Kg<0A>
Line4=<0A>
Line5=<0A>
SumFormat=00.0000
LogDigits=4
PrintTrigger=ABCD
MinInterval=5000
Duplicate=1(Yes)