Mantracourt Electronics Limited
LC1 User Manual
3
Chapter 2 Installing the LCI
The LCI is supplied as a single PCB unit with four fixing centres to accommodate M4 screws. Case options
are IP65 ABS (as standard), stainless steel, or DIN rail mounting.
Installation of the LCI is simplified by the provision of six two-part plug-in connectors for wiring to the Host,
the load cells and the alarm relay.
Connection details are shown in the diagram below:-
LCI Connection Details
Important Note:
When connecting less than four load cells to the LCI, start at channel one and fill the remaining channels in
numerical order. Set the ‘no C’ parameter accordingly (see table below).
LCI Connections to LCB & ADW15 Details
LCI
LCA20
LCD20
LCB
ADW15
+Ex
+E & +S
+E & +S
+E & +S
5 & 6
+S
+IN
+IN
+IN
4
Scr
SCR
SCR
SCR
1
-S
-IN
-IN
-IN
3
-Ex
-E & -S
-E & -S
-E & -S
1 & 2