Manson Engineering Industrial SBC-9138 User Manual Download Page 4

e.  Power level meter 

 

Displays current power level (the % of output current selected, details please see section F) 

 
f. 

Charging status 

 

NORMAL: Charging with normal profile 

 

RECOND: Charging with Recondition mode 

 

g.  AH meter 

 

Displays total AH value for the charging 

 

h.  Backlight status 

 

To show the backlight status 

 

BL. ON: Backlight always ON 

 

BL. T: Backlight will ON for 5 minutes 

 

BL. OFF: Backlight OFF 

 

i. 

Run timer 

 

Displays unit total run-time 

 

B.  Battery Type Selection 

 
Make sure the charger is power OFF, use a small slot type screw driver to select the battery through Battery Selection 
Switch (4). Please refer to the label under the removable door for battery type selection list 
The LCD will display the battery type you selected after restart the charger. 
 
WET 

:  Flooded Type lead acid batteries (to which water can be added) Automotive or Deep Cycle 

AGM/GEL 

:  Sealed type (VRLA), AGM-GEL, Maintenance Free, Automotive or Deep Cycle lead acid batteries 

Calcium-Calcium  :  Sealed type (VRLA) Lead Acid batteries with Calcium content Automotive or Deep Cycle 
Power Supply 

:  to provide a constant voltage DC power 13.3V to the external load connected to the battery and at   

 

 

  the same time without over charging the battery 

 

B1.  Recommended Battery Capacity   

 
The  following  minimum  AH  capacities  are  a  generalized  suggestion,  some  batteries  can  take  higher  charge  current, 
check with battery manufacturers for charging batteries with smaller capacity.   

 
 

C.  Battery Charger Installation and Connection 

 
Observe the warnings & safety precautions before rushing to install and operate the charger. 
Check battery condition, fill up cells for wet battery, clean battery poles. 
Secure  the battery  charger in a  well  ventilated  place, make sure the mounting  surface is flat and  without  soft covering 
material or loose paper sheet. The air intake is at the left side and air outlet at the right side. Make sure both intake and 
outlet are not blocked. Never place charger on top of battery. 
 
Plug in the AC mains. The LCD will display “Welcome” and unit software version and then go through a self-test. 
The cooling fan spins at full speed for 3 seconds and a “Beep” sound by means of Self-Testing. 
 

 
Figure to show charger initial 

 

 

 

Figure to show internal DC fan is under checking 

 
 
 
 

Charger Model 

SBC-9138 , 12V/25A 

SBC-9238 , 24V/13A 

Battery Capacity 

20 AH - 250 AH   

10 AH - 125 AH 

Summary of Contents for SBC-9138

Page 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Page 2: ...ting The extensive protection with alarm and LED indications including the thermostatic decrease of charging current to shut down ensure a durable working life span even in harsh conditions for the ch...

Page 3: ...emovable temperature sensor RED battery clamp Battery positive pole BLACK battery clamp Battery negative pole 8 Removable temperature sensor To increase decrease charging voltage at low high battery t...

Page 4: ...de a constant voltage DC power 13 3V to the external load connected to the battery and at the same time without over charging the battery B1 Recommended Battery Capacity The following minimum AH capac...

Page 5: ...t GEL and Charging Current Selection Switch 5 for output current setting default at 100 When install in caravans and similar vehicles the connection to the supply mains is to be in accordance with nat...

Page 6: ...h slow flashing If the charger cannot go to Absorption mode within 20 hours the charger will automatically goes to Float mode so to prevent over charge the battery This is call safety timer Stage 4 AB...

Page 7: ...on mode in this charging cycle and the charging will be conducted after Absorption mode After entered into this mode the Recondition curve REC will display with slow flashing This will put the charger...

Page 8: ...hich is not affected by other cooling or heating source Or you can insert it into the power cable negative battery clamp factory pre mounted The reference temperature of this sensor is 25 C and compen...

Page 9: ...stuck or not working F5 Faulty battery F6 Battery temp over 60 C as detected by remote sensor F7 short circuit 5 sec shut down otherwise auto recover Remark F7 is for power supply only F8 Reverse pol...

Page 10: ...onnection Battery type select switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for lo...

Page 11: ...oise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP Outpu...