Manson Engineering Industrial SBC-9138 User Manual Download Page 2

Fig.1 

INTRODUCTION 

 

Congratulations on purchasing our new Multi-Stage (IU0U) Switching Mode Smart Battery Charger. 

 

This software based MCU control 7 stage smart charger is designed with user friendly features and software plus 
hardware protection. It is a set, connect and forget charger that ensures complete recharge of your battery. 
 
Your battery can be connected indefinitely to the charger which will enter into energy conservation mode to prevent over 
charging and save electricity bills. The battery state of charge and temperature are closely monitored, updated and 
logged by the MCU and the remote temperature sensor mounted on the supplied charger cable and heavy duty battery 
clamps. 
 
Though the charger basically is engineered to charge high capacity battery/ banks, it can be made to charge much 
smaller battery by selecting the right reduced output setting. This charger can also be converted to a fixed voltage power 
supply with one simple concealed which setting.   
 
The extensive protection with alarm and LED indications including the thermostatic decrease of charging current to shut 
down ensure a durable working life span even in harsh conditions for the charger and the battery. There are selections for 
WET, AGM, GEL and Calcium-Calcium battery types. Special evaluation, conditioning charging profiles are made for the 
WET type battery so to recover deeply discharged WET lead acid battery. 
 
There is a Power Supply (PS) mode to provide a constant voltage DC power 13.3V to the external load connected to the 
battery and at the same time without over charging the battery. 

 

Almost all the protections are controlled by the Micro-Processor. On start up, the chargers run a series of self tests on the 
protective functions, displays and critical components like the cooling fan.   

 

Intended Use: 

All  Automotive,  Marine,  Mobile  Home,  Electric  Scooters,  Golf  Carts,  Solar,  Deep  Cycle,  UPS  Standby,  Industrial  & 
Commercial Applications. 
 

A.  Control and Indicators 

 

 
 
1.  Charger status LCD display 
 

Display the charging status, charging voltage/ current, battery type selected and etc.

 

Details please see this section below. 

 
2.  Programming Port 

 

Factory use only 

 
 

Summary of Contents for SBC-9138

Page 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Page 2: ...ting The extensive protection with alarm and LED indications including the thermostatic decrease of charging current to shut down ensure a durable working life span even in harsh conditions for the ch...

Page 3: ...emovable temperature sensor RED battery clamp Battery positive pole BLACK battery clamp Battery negative pole 8 Removable temperature sensor To increase decrease charging voltage at low high battery t...

Page 4: ...de a constant voltage DC power 13 3V to the external load connected to the battery and at the same time without over charging the battery B1 Recommended Battery Capacity The following minimum AH capac...

Page 5: ...t GEL and Charging Current Selection Switch 5 for output current setting default at 100 When install in caravans and similar vehicles the connection to the supply mains is to be in accordance with nat...

Page 6: ...h slow flashing If the charger cannot go to Absorption mode within 20 hours the charger will automatically goes to Float mode so to prevent over charge the battery This is call safety timer Stage 4 AB...

Page 7: ...on mode in this charging cycle and the charging will be conducted after Absorption mode After entered into this mode the Recondition curve REC will display with slow flashing This will put the charger...

Page 8: ...hich is not affected by other cooling or heating source Or you can insert it into the power cable negative battery clamp factory pre mounted The reference temperature of this sensor is 25 C and compen...

Page 9: ...stuck or not working F5 Faulty battery F6 Battery temp over 60 C as detected by remote sensor F7 short circuit 5 sec shut down otherwise auto recover Remark F7 is for power supply only F8 Reverse pol...

Page 10: ...onnection Battery type select switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for lo...

Page 11: ...oise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP Outpu...