3.  Recondition mode switch 

 

Simple press and hold 3 seconds the switch to set the charger to go with recondition charge in next cycle. 

 

4.  Battery selection switch 

 

For Wet, AGM, GEL, Calcium-Calcium and Power supply mode. (Default at position 3 the GEL type) 

 

5.  Charging current selection switch (Manual de-rating) 

 

Current can be selected to 20%, 40%, 60%, 80% and 100% of the max current. Details please see the label 

 

under the moveable door. (Default at 100%) 

 

6.  Back Light ON/OFF switch (Only for SBC-9138/9238) 

 

Toggle ON/OFF the backlight by pushing the removable door, no need to open the door. 

 

Press x 1  :  Backlight ON for 5 minutes 

        Press x 2  :  Backlight always ON 
        Press x 3  :  To turn backlight OFF   

 
7.  Charging cable with removable temperature sensor 

 

RED battery clamp– Battery positive pole 

 

BLACK battery clamp– Battery negative pole 

 

8.  Removable temperature sensor 

 

To increase/ decrease charging voltage at low/ high battery temperature 

 
9.  Ventilation Fan 

 

Thermostatic control fan from zero to full speed 

 

10.  AC input power cord 
 

LCD Display Indication 

 

 

a.  Charging status curve 

 

To show the battery charging status 

 

DES: Desulphation charge (charging with pulse charge) 

 

SST: Soft start (charging with 1/2 the max current) 

 

BUL: Bulk charge (charging with constant max. current) 

 

ABS: Absorption (charging with preset constant voltage) 

 

REC: Recondition charge (for WET battery type only) 

 

FLO: Float charge (charging with preset constant voltage) 

 

STA: Standby (charging with 96% of the preset constant float voltage) 

 
b.  Voltmeter 

 

Displays the charging voltage 

 
c.  Ammeter 

 

Displays the charging current 

 
d.  Battery type 

 

Displays the battery type selected 

 

Summary of Contents for SBC-9138

Page 1: ...not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face awa...

Page 2: ...ting The extensive protection with alarm and LED indications including the thermostatic decrease of charging current to shut down ensure a durable working life span even in harsh conditions for the ch...

Page 3: ...emovable temperature sensor RED battery clamp Battery positive pole BLACK battery clamp Battery negative pole 8 Removable temperature sensor To increase decrease charging voltage at low high battery t...

Page 4: ...de a constant voltage DC power 13 3V to the external load connected to the battery and at the same time without over charging the battery B1 Recommended Battery Capacity The following minimum AH capac...

Page 5: ...t GEL and Charging Current Selection Switch 5 for output current setting default at 100 When install in caravans and similar vehicles the connection to the supply mains is to be in accordance with nat...

Page 6: ...h slow flashing If the charger cannot go to Absorption mode within 20 hours the charger will automatically goes to Float mode so to prevent over charge the battery This is call safety timer Stage 4 AB...

Page 7: ...on mode in this charging cycle and the charging will be conducted after Absorption mode After entered into this mode the Recondition curve REC will display with slow flashing This will put the charger...

Page 8: ...hich is not affected by other cooling or heating source Or you can insert it into the power cable negative battery clamp factory pre mounted The reference temperature of this sensor is 25 C and compen...

Page 9: ...stuck or not working F5 Faulty battery F6 Battery temp over 60 C as detected by remote sensor F7 short circuit 5 sec shut down otherwise auto recover Remark F7 is for power supply only F8 Reverse pol...

Page 10: ...onnection Battery type select switch in wrong setting Battery capacity too large Ambient temperature too low Battery has damaged cell or battery is too old Wrong set the lower power level Check for lo...

Page 11: ...oise Peak to Peak 200mV Efficiency at WET 230VAC 85 Protections Short Circuit Protection Yes Overload Protection Yes Reverse Polarity Protection by Mosfet Yes Over Temperature Protection Yes OVP Outpu...