Manson Engineering Industrial SBC-5936 Operation Manual Download Page 7

PV LED

The PV LED is ON  when voltage from PV panel is >14.4V. PV LED flickers  with the changes of PV 
voltages. PV LED is off at night time .This is a good way to check for open- circuit in the solar connection

 

in 

day time.

Battery Type Selection

1.

Press and hold the only Set Button for about 5 seconds until the LED flashes.

2.

Light quick presses will move the LED from Lead--> AGM--> LiFePO4--> Lead. 

3.

Stop at the chosen battery type and wait till LED stops flashing to confirm your selection.

Connections

After both input and output are connected, the charger will have output after 10 Sec.

Fig 3. : Terminals & 8PIN connectors

1

T+:

Vibration sensor enable pin. Connect to Vout for Ignition pin to enable Vibration
sensor control.

2

Red:

Connection to remote module Red wire.

3

Green:

Connect to remote module green wire.

4

Yellow:

Connect to remote module yellow wire.

5

Alarm:

Alarm output pin. 12V 50mA for external alarm.

6

GND:

Ground pin for remote module. Connect to remote control black wire.

7

Ignition:

Connect this pin to ignition car ignition to make the charger operate in sync with
vehicle ignition control.

8

Vout for Ignition:

Short this pin to pin 7 (Ignition) to enable manual ignition control of unit to ON.
Short this pin to Pin1( T+ ) to enable vibration sensor mode.

*This   pin   is   for  Manual   On/Off  or  Vibration   sensor   only.   Don’t   connect   to   other
devices.

Solar panel and DC source Dual inputs

The charger supports 12V Solar panel and 12V or 24V DC source inputs. Both inputs can be connected 
simultaneously to the charger or either one. Charger uses Solar energy as priority source to charge battery 
to maximize the usage of Solar panel. The PV LED and charging output will be switched ON whenever the 
Solar panel has sufficient energy for charging. The Vibration sensor, automatic ignition control and manual 
on off control have on effect on solar panel input charge.
*The allowable maximum power rating of solar panel is 400 Watt with maximum 30V Open Circuit voltage.

P.7

Summary of Contents for SBC-5936

Page 1: ...her types of battery or under sized lead acid batteries may cause fire or explosion Install the charger in accordance with all local codes Do not use the charger if it has been dropped or damaged Neve...

Page 2: ...or liability of losses damages and related expenses whether specific direct indirect consequential or accidental which might result from the use of information given in this manual 3 Shall not be liab...

Page 3: ...ls P 6 Battery Type selection P 7 Solar panel and DC source dual inputs P 7 Charger control modes P 8 Connect Wiring Diagram P 10 Specification P 11 Troubleshooting P 12 Figure index Fig 1 correct ins...

Page 4: ...charging is specially for the LiFePO4 battery and charging current stops at the end of Absorption Stage Three Charge Control Methods Ignition Control Charger starts charging only when ignition is on...

Page 5: ...t heat and rain Allow at least 80mm of space at both ends for ventilation We recommend wiring by a qualified automobile electrician to ensure local safety and on board standard are followed 1 To provi...

Page 6: ...harging status LED Charging stage Fast flashes Bulk charge Slow flashes Absorption Solid Float Charging Status LED for Lithium Fe PO4 Battery 2 Stages Charging status LED Charging stage Fast flashes B...

Page 7: ...0mA for external alarm 6 GND Ground pin for remote module Connect to remote control black wire 7 Ignition Connect this pin to ignition car ignition to make the charger operate in sync with vehicle ign...

Page 8: ...n is simple and quick and without touching the car s electrical system for the sensor to work Enable build in vibration sensor The built in vibration sensor is enabled by connecting the T pin 1 to Vou...

Page 9: ...or with sufficiently high and stable charging voltage This Control Mode is not suitable for modern cars due to wide voltage range such as Euro 5 6 Cancel the Ignition Control first in order to get int...

Page 10: ...fuse breaker is required to be close to starting battery charger input and close to house battery charger output wire Fuse at the solar panel to the rating of the short circuit current of the solar pa...

Page 11: ...x 188 x 55mm Weight Approx 870g Operating Temperature 10 to 40 C Ambient Temperature Recommended Cable Size Cable Length Recommended SAE 1 5 Meters 8AWG 5 9 Meters 6AWG Operating Mode 12V CAR 24V CAR...

Page 12: ...ection First layer by software Second layer by hardware Fault LED ON Software OVP Output terminal voltage set absorption Voltage 0 6V for 2s Disconnect any load to battery and check battery voltage If...