Specification

Rated output power

12A at 27.6VDC

Efficiency

90%

Input Voltage
DC Input Voltage Range

9 - 16VDC (12VDC Input) / 18 - 32VDC (24VDC Input)

Max. Solar Panel Open Circuit Voltage

30VDC

 

No load input current

<25mA

Output (Charge) Voltage

Battery Type

Absorption

Float

Lead

27.6V

26.6V

AGM

29.4V

27.2V

LiFePO4

29.6V

Stop

Alarm Output

12V / 100mA

Size(L x W x H)mm

130 x 188 x 55mm

Weight

Approx. 870g

Operating Temperature

-10 to +40ºC (Ambient Temperature)

Recommended Cable Size
Cable Length

Recommended SAE

1 – 5 Meters

8AWG

5 – 9 Meters

6AWG

Operating Mode

12V CAR

24V CAR

Vibration Sensor Mode

Charge ON
11-16V

Charge OFF
<9V

Charge ON
22-32V

Charge OFF
<18V

Ignition Feed – Automatic Mode

Charge ON
11-16V

Charge OFF
<9V

Charge ON
22-32V

Charge OFF
<18V

Factory Preset Mode

Charge ON
12.8-16V

Charge OFF
<12.2V

Charge ON
25.6-32V

Charge OFF
<24.4V

Recommended PV Panel Size
PV Panel Size

400Watt with maximum 30V open circuit voltage

P.11

Summary of Contents for SBC-5936

Page 1: ...her types of battery or under sized lead acid batteries may cause fire or explosion Install the charger in accordance with all local codes Do not use the charger if it has been dropped or damaged Neve...

Page 2: ...or liability of losses damages and related expenses whether specific direct indirect consequential or accidental which might result from the use of information given in this manual 3 Shall not be liab...

Page 3: ...ls P 6 Battery Type selection P 7 Solar panel and DC source dual inputs P 7 Charger control modes P 8 Connect Wiring Diagram P 10 Specification P 11 Troubleshooting P 12 Figure index Fig 1 correct ins...

Page 4: ...charging is specially for the LiFePO4 battery and charging current stops at the end of Absorption Stage Three Charge Control Methods Ignition Control Charger starts charging only when ignition is on...

Page 5: ...t heat and rain Allow at least 80mm of space at both ends for ventilation We recommend wiring by a qualified automobile electrician to ensure local safety and on board standard are followed 1 To provi...

Page 6: ...harging status LED Charging stage Fast flashes Bulk charge Slow flashes Absorption Solid Float Charging Status LED for Lithium Fe PO4 Battery 2 Stages Charging status LED Charging stage Fast flashes B...

Page 7: ...0mA for external alarm 6 GND Ground pin for remote module Connect to remote control black wire 7 Ignition Connect this pin to ignition car ignition to make the charger operate in sync with vehicle ign...

Page 8: ...n is simple and quick and without touching the car s electrical system for the sensor to work Enable build in vibration sensor The built in vibration sensor is enabled by connecting the T pin 1 to Vou...

Page 9: ...or with sufficiently high and stable charging voltage This Control Mode is not suitable for modern cars due to wide voltage range such as Euro 5 6 Cancel the Ignition Control first in order to get int...

Page 10: ...fuse breaker is required to be close to starting battery charger input and close to house battery charger output wire Fuse at the solar panel to the rating of the short circuit current of the solar pa...

Page 11: ...x 188 x 55mm Weight Approx 870g Operating Temperature 10 to 40 C Ambient Temperature Recommended Cable Size Cable Length Recommended SAE 1 5 Meters 8AWG 5 9 Meters 6AWG Operating Mode 12V CAR 24V CAR...

Page 12: ...ection First layer by software Second layer by hardware Fault LED ON Software OVP Output terminal voltage set absorption Voltage 0 6V for 2s Disconnect any load to battery and check battery voltage If...

Reviews: