background image

Q

IEC POWER RECEPTACLE:  The power cable shipped with the converter
connects into this socket.

R

FUSE HOLDER:  Replace only with 1 AMP 220 Volt similar type.

T

GROUND TERMINAL: Chassis Ground. Some installations may be helped by
connecting a wire from this terminal to the preamplifier. Also this may require that
the third pin mains ground be disconnected. The easiest and best way to do this is a 3
pin to 2 pin adapter available in most hardware stores. Keep in mind that this is
slightly dangerous in a mis-wired system and could put potentially lethal voltages on
the chassis. This pin grounded to the preamplifier chassis should make it safe.

U

AT&T INPUT:  Digital Glass Fiber Intputs. Very recommended if you have the
choice. This is not a TOSLINK input. These connectors require a quarter turn
clockwise to lock. They can be fragile so some degree of gentleness is best when
connecting / disconnecting or moving the converter.

V

AES / EBU INPUTS: Balanced transformer floating 110 Ohm digital inputs. Use
110 Ohm cable only. Some people suggest disconnecting the cable shield at the male
XLR that is connected to the converter or connecting the shield through a good .1
microfarad capacitor.

W

S/PDIF / AES SWITCHES: Each channel should only have either an AES or SPDIF
input and not both. The switch should be up if AES is used or down if SPDIF is used.
The switch matches input impedance and level to established standards. This
minimizes cable reflections and jitter.

X

S/PDIF INPUTS: These are floating transformer inputs. Use 75 OHM COAX cable
designed for digital or as a lesser alternative good video cable. Do not use standard
audio interconnects. While these cables may pass the digital data, they will likely
increase the jitter quantity because they are not designed to pass signals in the tens of
megahertz. Digital data requires a 5 megahertz bandwidth minimum and significantly
higher for good quality square wave signals.

Summary of Contents for MANLEY REFERENCE DIGITAL TO ANALOGUE CONVERTER

Page 1: ...ORATORIES INC OWNER SMANUAL MANLEY REFERENCE DIGITAL TO ANALOGUE CONVERTER MANLEY LABORATORIES INC 13880 MAGNOLIA AVE CHINO CA 91710 TEL 909 627 4256 FAX 909 628 2482 emanley netcom com http www manle...

Page 2: ...CONTENTS INTRODUCTION 3 MAINS CONNECTIONS 4 FIGURE 1 FRONT PANEL 5 FIGURE 2 REAR PANEL 6 INTERNAL 8 WARRANTY 10 WARRANTY REGISTRATION 11 SECTION PAGE...

Page 3: ...or 18 bits through this device allows up to 24 bits through The only digital processing used is the HDCD filter chip Not only does it provide the path for HDCD recordings it is also the best performin...

Page 4: ...TRAL terminal BROWN LIVE terminal As the colours of the wires in the mains lead may not correspond with the coloured marking identifying the terminals in your plug proceed as follows The wire which is...

Page 5: ...onds 2 momentary loss of data including changing the DIGITAL INPUT SELECT 3 any cable related loss of data unreadable data or data errors 4 The phase locked loop has not yet locked or electronic latch...

Page 6: ...t recordings already have done this J DITHER LED Lit when the DITHER SWITCH is on K POWER LED Lit when the POWER SWITCH is on L POWER SWITCH The single most important control to master M N O P Q R S T...

Page 7: ...is best when connecting disconnecting or moving the converter V AES EBU INPUTS Balanced transformer floating 110 Ohm digital inputs Use 110 Ohm cable only Some people suggest disconnecting the cable...

Page 8: ...plifiers and does not attenuate any tube problems Manley always has good tubes in stock if needed The all tube line amplifier is a combination of our tried and true totem output but with a new differe...

Page 9: ...ECTOR SWITCH PHASE POLARITY SWITCH 3 S PDIF INPUTS 3 AES EBU INPUTS AT T OPTICAL INPUT BOTH UNBALANCED AND BALANCED ANALOGUE OUTPUTS LED INDICATORS FOR VALID DATA HDCD ERROR EMPH Etc PRECISION MILLED...

Page 10: ...rwarrantyregistrationcard IfaManleyLaboratories productfailstomeettheabovewarranty thenthepurchaser ssole remedyshallbetoreturntheproducttoManleyLaboratories wherethedefectwillberepaired withoutcharge...

Page 11: ...ALNo ______________________ PURCHASE DATE __________ SUPPLIER __________________ PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES MODEL _________________SERIAL No __________________ PURCH...