Refrigeration System
Section 7
7-20
Part Number 80-1630-3
Cycle Time/24 Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
•
Refer to “OPERATIONAL ANALYSIS TABLE” for the
list of data that must be collected for refrigeration
diagnostics. This list includes: before beginning
service, ice production check, installation/visual
inspection, water system checklist, ice formation
pattern, safety limits, comparing evaporator inlet/
outlet temperatures, discharge and suction pressure
analysis.
•
Ice production checks that are within 10% of the
chart are considered normal. This is due to variances
in water and air temperature. Actual temperatures
will seldom match the chart exactly.
•
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
•
Discharge and suction pressure are highest at the
beginning of the cycle. Suction pressure will drop
throughout the cycle. Verify the pressures are within
the range indicated.
•
Record beginning of freeze cycle suction pressure
one minute after water pump energizes.
•
Regular cube production derate is 7%
•
50Hz production derate is 7%
S600M SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
7.6-9.0
7.9-9.4
8.6-10.1
1-2.5
80/26.7
7.8-9.2
8.1-9.5
8.8-10.3
90/32.2
7.9-9.4
8.2-9.7
8.8-10.3
100/37.8
8.1-9.5
8.4-9.9
9.1-10.7
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
650
630
590
80/26.7
640
620
580
90/32.2
630
610
580
100/37.8
620
600
560
Based on average ice slab weight of 4.12 - 4.75lb
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
36-26
140-190
65-95
70/21.1
225-235
36-26
140-190
65-95
80/26.7
225-245
40-28
150-195
70-100
90/32.2
230-255
40-29
160-200
70-100
100/37.8
230-260
40-30
170-205
75-105
110/43.3
230-260
40-30
180-210
80-110
Suction pressure drops gradually throughout the freeze cycle
Summary of Contents for S600M
Page 24: ...Ice Machine Operation Section 3 3 6 Part Number 80 1630 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 100: ...Refrigeration System Section 7 7 34 Part Number 80 1630 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 101: ...Section 7 Refrigeration System Part Number 80 1630 3 7 35 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 102: ......