Electrical System
Section 6
6-10
Part Number 80-1630-3
S600M - SELF CONTAINED - 1 PHASE
SV3130
(89)
(55)
(88)
(42)
High Pressure
Cutout
Water Valve
Harvest Valve
Dump Valve
Water Pump
Terminates at
Pin Connection
(20)
(21)
(22)
(74)
Ice Thickness
Probe
Water Level Probe
Control
Board
(61)
(60)
(57)
(98)
(99)
(76)
(81)
(75)
(77)
(80)
(26)
(25)
(58)
(59)
Contactor
Coil
(56)
Trans.
Fuse (7a)
Low DC
Voltage
Plug
L1
(51)
(85)
(86)
Fan Cycle
Control
Fan Motor
Run Capacitor
PTCR
Compressor
Run
Capacitor
(50)
(45)
L2 or N
L1
Ground
(2)
(6)
(5)
(1)
(7)
(4)
L2
Air Compressor
(When Used)
Bin Switch
Clean
OFF
ICE
(2)
(1)
(6)
(8)
(9)
Overload
(Red)
(Yellow)
(Black)
Contactor
Contacts
(46)
(99)
Clean
Left Bin
Right Bin
Wtr Probe
Rmt Bin
Ice Probe
Harvest
SL-2
SL-1