Installation Instructions
Section 2
2-6
Part Number 000001759
Q460 - Q1090 Ice Machines
SELF CONTAINED ICE MACHINE
230/1/50
Remote Electrical Wiring Connections
REMOTE ICE MACHINE WITH SINGLE CIRCUIT
MODEL CONDENSER 230/1/50
Ice
Machine
Voltage Phase
Cycle
Air-Cooled
Remote
Maximum Fuse/
Circuit Breaker
Minimum Circuit
Amps
Maximum Fuse/
Circuit Breaker
Minimum Circuit
Amps
Q460
230/1/50
15
6.7
N/A
N/A
Q660
230/1/50
15
9.2
N/A
N/A
Q1060
230/1/50
20
15.6
20
14.6
Q1090
230/1/50
N/A
N/A
20
14.6
!
Warning
These diagrams are not intended to show proper
wire routing, wire sizing, disconnects, etc., only the
correct wire connections.All electrical work,
including wire routing and grounding, must conform
to local and national electrical codes.
L1
L1
L2
L2
GROUND
GROUND
ICE MACHINE
CONNECTIONS
TO SEPARATE
FUSE/BREAKER.
DISCONNECT ALL
POLES.
SV1191
SINGLE CIRCUIT
REMOTE
CONDENSER
L
1
L
2
NOTE: FAN
MOTOR IS
220-240V
L
1
N
F
2
F
1
ICE
MACHINE
GROUND
L
1
N
GROUND
TO SEPARATE
FUSE/BREAKER
(220-240).
DISCONNECT ALL
POLES.
SV1256