Section 2
Installation Instructions
Part Number 000001759
2-3
Location of Ice Machine
The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
• The location must be free of airborne and other
contaminants.
• The air temperature must be at least 1.6°C, but must
not exceed 43.4°C.
• The location must not be near heat-generating
equipment or in direct sunlight.
• The location must not obstruct air flow through or
around the ice machine. Refer to the chart below for
clearance requirements.
Stacking Two Ice Machines on a Single
Storage Bin
A stacking kit is required for stacking two ice machines.
Installation instructions are supplied with the stacking kit.
Ice Machine Heat of Rejection
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing
air conditioning equipment where self-contained air-
cooled ice machines are installed.
This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added
to an air conditioned environment by an ice machine
using a water-cooled or remote condenser is negligible.
Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled
condenser. Use the peak figure for sizing the cooling
tower.
Q Models
Self-Contained
Air-Cooled
Remote
Top/Sides
203 mm
203 mm
Back
127 mm
127 mm
There is no minimum clearance required. This value is
recommended for efficient operation and servicing only.
!
Caution
The ice machine must be protected if it will be
subjected to temperatures below 0° C. Failure
caused by exposure to freezing temperatures is not
covered by the warranty. See “Removal from
Service/Winterization”.
Q460/Q660/
Q1060
Stacked
Self-Contained
Air-Cooled
Stacked
Remote
Top/Sides
406 mm
127 mm
Back
127 mm
127 mm
Series
Ice Machine
Heat of Rejection
B.T.U./Hour
Air Conditioning
Because the heat of rejection varies during the ice making cycle,
the figure shown is an average.
Peak
Q460
7,000
9,600
Q660
9,000
13,900
Q1060
16,000
24,700