CONTROLS AND OPERATING PROCEDURES
OPERATOR MANUAL
NBT50
3-10
Published 03-23-2018 Control # 243-14
The RCL bypass switch (6, Figure 3-4) located behind the
cab seat, below the fuse relay panel, is an off/on switch and
will bypass the overloaded controls until the switch is turned
to the OFF position.
The RCL will be bypassed only as long as the switches are in
the ON position.
Turning the key switch to the ON position re-engages the
boom down, telescope out and hoist up controls. These
functions were disabled when an overload condition was
sensed by the Rated Capacity Limiter (RCL). It is important
to read and understand the RCL Override information before
using the RCL bypass on/off switch. For detailed information
concerning the operation and maintenance of the RCL
system installed on the crane, see Section 7 - Rated
Capacity Limiter in this manual.
Emergency Stop Switch
The crane emergency stop switch (9, Figure 3-4) is located
on the cab console and is used to shut down the truck engine
in an emergency. Push the red button in to shut down the
engine, rotate the knob and pull out to resume normally
operation.
NOTE:
Only use the emergency stop switch in the case of
an emergency to shut down the engine; do not use
the emergency stop switch regularly as a means of
turning off the machine.
AC/Heater Vent
The cab has air conditioner and heating vents (10,
Figure 3-4), located on the control panel, behind the panel,
under the seat and at head level.
Crane Ignition Switch
The crane ignition switch (11, Figure 3-4) is located on the
crane cab console and controls the truck engine and crane
cab power. The ignition switch has three positions. OFF
shuts down engine and cab power, ON activates truck
engine ignition as well as all cab power, and Start is truck
engine start.
12V Receptacle
This 12 volt accessory outlet (12, Figure 3-4) is located on
the lower part of the front control panel and is designed to
mate with most 12 volt adapter plugs.
Diagnostic Connector
The diagnostic connector (13, Figure 3-4) is located on the
lower part of the front control panel. It is used for servicing
the cab and crane’s electrical system.
A laptop computer with an RS232 port (nine pin cable
connector) and the appropriate electrical system software
are required. Contact Manitowoc Crane Care to obtain the
appropriate diagnostic cable.
Level Indicator
The bubble level indicator (14, Figure 3-4) is located on the
right interior wall of the cab. The indicator provides the
operator with a visual indication for determining the
levelness of the machine.
Engine Hi/Low Switch
The truck engine Hi/Low Switch (15, Figure 3-4) is located
on the right overhead console.
It is a two position (+/-) momentary switch that is a secondary
throttle control which provides idle-control inputs that
increase and decrease the truck engine idle.
This is an increment/decrement style switch, press and
release the (+) or (-) side of the switch to increase or
decrease idle speed incrementally.
Press and hold the switch in either the Hi or Low direction
and the engine will ramp to maximum RPM or minimum
RPM.
Crane Function Power Switch
The crane function power switch (16, Figure 3-4) is located
on the right overhead console. The switch has two positions:
OFF takes all power from the joy stick controllers on the arm
rest and from the swing brake unlock (assuring the brake
stays locked). The OFF position prevents inadvertent
operation of these functions and assures the swing brake is
set when the crane is not powered. The ON position will
restores power to the joy stick controllers and the swing
brake.
Remote Power Switch (Optional)
The radio remote switch (17, Figure 3-4) is used to enable
the radio remote controls. The crane function power switch,
and truck ignition must all be OFF before the crane can be
operated with a radio remote control. The crane ignition
switch must be in the ON position.
Work Light Switch
The work light switch (18, Figure 3-4) is a two position rocker
switch, ON and OFF, located on the right overhead console.
It turns the cab outside working lights on or off.
Dimmer Light Switch
The dimmer light control (19, Figure 3-4) dims the light for
the AC/heater control knob (23).
Summary of Contents for National Crane NBT50 Series
Page 1: ...Operator Manual National Crane NBT50 Series ...
Page 2: ......
Page 10: ...TOC 6 TABLE OF CONTENTS OPERATOR MANUAL NBT50 THIS PAGE BLANK ...
Page 12: ...INTRODUCTION OPERATOR MANUAL NBT50 1 2 Published 03 23 2018 Control 243 14 FIGURE 1 1 7650 66 ...
Page 157: ......
Page 158: ......