National Crane
Published 03-23-2018 Control # 243-14
7-17
NBT50 OPERATOR MANUAL
RATED CAPACITY LIMITER
7
Base Side Pressure Sensor Calibration
Press OK to disconnect electrical cable (port LMI 2) to rod
side transducer, per top paragraph on the screen and then
follow the instructions as they appear on the screen.
-
Pressing OK sends a signal to the transducer to re-
program and power down.
-
When prompted by the bottom screen paragraph,
reconnect rod side sensor to manifold and press OK
to return to the main sensor calibration screen
(page 7-15).
Outrigger Span/Length
Select 7 from the Main Sensor Calibration Menu screen
(page 7-15) to start the outrigger length sensor calibration.
Outrigger Length Sensor Calibration
Three calibration positions are shown on the Outrigger
Length Sensor Calibration screen one at a time starting with
the Fully Retract position.
Pressing OK at the activated position automatically actives
the next position.
If an error screen appears after OK is pressed, the outrigger
sensor for that screen will have to be checked for proper
function and wiring.
See new error screen to communicate which sensor or
sensors need investigation.
CWT Switch Panel Calibration
If equipped, Select 8 from the Main Sensor Calibration Menu
(page 7-15) to begin CWT panel calibration.
CWT Panel Calibration
Confirm that you have disconnected the proper electrical
connection and follow the instructions as they appear on the
screen.
Load Chart and RCL Up-load
Software upgrades, Main Load Chart and the Calibration
Chart are up-loaded to the RCL system using a laptop
computer connected to the crane control system through the
Diagnostic Connector (1, Figure 7-7) in the operator’s cab
control panel. Contact the distributor for the required
software and cables for crane interface.
Connect the laptop to the Diagnostic Connector (1,
Figure 7-8) with the interface cable.
If the RCL is in the start up mode and at the Main Menu
screen (Figure 7-2), select function key 2, Tools.
At the Main Sensor Calibration Menu (page 7-15), select
function key 6 (use arrow keys to scroll).
7769-56
7623-40
7769-60
FIGURE 7-8
7459-18
1
1
Summary of Contents for National Crane NBT50 Series
Page 1: ...Operator Manual National Crane NBT50 Series ...
Page 2: ......
Page 10: ...TOC 6 TABLE OF CONTENTS OPERATOR MANUAL NBT50 THIS PAGE BLANK ...
Page 12: ...INTRODUCTION OPERATOR MANUAL NBT50 1 2 Published 03 23 2018 Control 243 14 FIGURE 1 1 7650 66 ...
Page 157: ......
Page 158: ......