Part Number 000012545 Rev 02 11/16
15
Section 2
Installation
Remote Condenser/Line Set Installation
Ice Machine
Remote Single
Circuit Condenser
Line Set*
K1000
KC1000
RTK-20-R410A
RTK-35-R410A
RTK-50-R410A
K1350
KC1350
RLK-20-R410A
RLK-35-R410A
RLK-50-R410A
K1800
KC1350
RLK-20-R410A
RLK-35-R410A
RLK-50-R410A
*Line Set
Discharge Line
Liquid Line
RTK
1/2" (1.27 cm)
5/16" (.79 cm)
RLK
1/2" (1.27 cm)
3/8" (.95 cm)
Air Temperature Around the Condenser
Minimum
Maximum
-20°F (-29°C)
120°F (49°C)
Important
Remote systems are only approved and warranted as a
complete new package. Warranty on the refrigeration
system will be void if a new ice machine head section
is connected to pre-existing (used) tubing or remote
condensers.
REMOTE ICE MACHINE REFRIGERANT CHARGE
Each remote ice machine ships from the factory with a
refrigerant charge appropriate for installation with line
sets of up to 50' (15 m). The serial tag on the ice machine
indicates the refrigerant charge.
Additional refrigerant may be required for installations
using line sets between 50' and 100' (15-30 m) long. If
additional refrigerant is required, refer to the chart below
for the correct amount to be added.
Ice Machine
Refrigerant to be added for
50'-100' Line Sets
K1000
2 lbs (907g)
K1350
2 lbs (907g)
K1800
2 lbs (907g)
Important
EPA CERTIFIED TECHNICIANS
If remote line set length is between 50' and 100'
(15 and 30 m), add additional refrigerant to the
nameplate charge. Refer to the table below for the
model being worked on.
Tubing length: _________________________________
Refrigerant added to nameplate: __________________
New total refrigerant charge: _____________________
n
Warning
Potential Personal Injury Situation
The ice machine contains refrigerant charge. Installation
of the line sets must be performed by a properly trained
and EPA certified refrigeration technician aware of
the dangers of dealing with refrigerant charged
equipment.