Clean and sanitize ice machine 

(continued)

 

 

©McDonald’s Corporation · Planned Maintenance Manual · Revised AUGUST 2016 

Page 2 of 4

 

Ma

nitowoc Ice Ma

ch

in

e Mode

ls 

Ind

igo

 

Monthly 

BE 13 M1

Prepare DeLimer solution. 

Follow label instructions to 
prepare the correct amount of 
delimer. 
 
For models: 

I300, I320, I420

 

Kay Delimer - Mix 2 packets 
with 1 liter of warm water 
or 
McD KL - Measure 120 ml 

 
I1200, I1400, I1600, I1800

 

Kay Delimer - Mix 5 packets 
with 1 liter of  warm water 
or 
McD KL - Measure 290 ml 

 
For all other models

 

Kay Delimer - Mix 4 packets 
with 1 liter of water  
or 
McD KL - Measure 200 ml 
 

*Amounts vary by ice machine size 
due to amount of water being held in 
the water trough of each machine.  
Larger machines hold more water.  
Concentration should remain the 
same.  

 

 

DeLimer  

 

 

 
 

 

 
 

 
 

Press CLEAN switch. 

Push the clean button to  
start the cleaning process. 

 

 

 

 

Delime evaporator and water 
circulation system. 

Wait for approximately 2 
minutes until water starts to 
flow over the evaporator, then 
pour the premixed solution 
into the water trough.  

 

 

Allow clean cycle to run. 

The ice machine will auto-
matically run through a wash 
cycle and several rinse cycles. 
The entire cycle lasts  
approximately 30 minutes.  
 
Countdown clock will let you 
know duration and time re-
maining  

 

 

Turn off power to the ice 
machine.  

 

Do not begin cleaning other 
parts of the ice machine until 
it is unplugged or  
breaker/disconnect is turned 
off. 

 

 

Remove water curtain.  

Gently flex the curtain in the 
center and remove it from the 
right side.  Slide the left pin 
out.

 

 

 

10 

Remove the ice thickness 
probe.  

Compress the hinge pin on 
the top of the ice thickness 
probe.  
 
Pivot the ice thickness probe 
to disengage one pin then the 
other. The ice thickness probe 
can be cleaned at this point 
without complete removal. If 
complete removal is desired, 
disconnect the ice thickness 
control wiring from the  
control board.  

 

Summary of Contents for I300

Page 1: ...lean towels Bucket soiled towels Ice scoop Kay Delimer McD KL Delimer Kay 5 Sanitizer McD DR Sanitizer Multi Surface Glass Cleaner Screwdriver Phillips Procedure 1 Remove front panel Use a Phillips screwdriver to loosen the two screws secur ing the door Do not remove screws completely they are secured to prevent loss 2 Turn ice machine off After ice has fallen from the evaporator turn the machine ...

Page 2: ...process 6 Delime evaporator and water circulation system Wait for approximately 2 minutes until water starts to flow over the evaporator then pour the premixed solution into the water trough 7 Allow clean cycle to run The ice machine will auto matically run through a wash cycle and several rinse cycles The entire cycle lasts approximately 30 minutes Countdown clock will let you know duration and t...

Page 3: ...l probe Pull the water level probe straight down to disengage Lower the water level probe until the wiring connector is visible Disconnect the wire lead from the water level probe Remove the water level probe from the ice machine 15 DeLime plastic parts Mix the correct amount of delimer with 4 gallons 15 liters of warm water in a three compartment sink Kay Delimer 4 packets or McD KL 150 ml Place ...

Page 4: ... packets with 1 liter of water McD DR Measure 40 ml Amounts vary by ice machine size due to amount of water being held in the water troughs of each machine Larger machines hold more water Concentration should remain the same Sanitizer 22 Press CLEAN switch The clean light will turn on to indicate the machine is in the sanitize cycle Check box to return to ON start ice making at the completion of s...