![Manitowoc Grove RT765E-2 Service And Maintenance Manual Download Page 134](http://html.mh-extra.com/html/manitowoc/grove-rt765e-2/grove-rt765e-2_service-and-maintenance-manual_701214134.webp)
ELECTRICAL SYSTEM
RT765E-2 SERVICE MANUAL
3-6
Published 9-04-2014, Control # 422-08
Ignition key switch is in the ACC and RUN positions.
ACC Relay #2 is not energized while in START position.
.
4
5
6
7
8
9
1
2
3
Item
Description
1
Power Relay (K301)
2
Start Relay (K303)
3
Grid Heater Relay (K302)
4
250 Amp Fuse (F53)
5
100 Amp Fuse (F54)
6
100 Amp Fuse (F55)
7
100 Amp Fuse (F56)
8
100 Amp Fuse (F52)
9
250 Amp Fuse (F51)
10
Fuse and Relay Panel (see Figure 3-7)
FIGURE 3-6
10
FIGURE 3-7
5
6
7
4
3
2
1
Item
Description
1
ECM, 30 Amp Fuse (F1)
2
Cranestar, 5 Amp Fuse (F2)
3
Carrier, Rear Module, 25 Amp Fuse (F3)
4
Carrier, Rear Module, 30 Amp Fuse (F4)
5
Carrier, Front Module, 30 Amp Fuse (F5)
6
Power Control Relay, 5 Amp Fuse (F6)
7
120 Ohm Resistor, Starter Lockout Circuit
8
Relay KC1, Power Control Relay
Relay KC2, Remote Crank Relay
7860
8
9
Reference Only