Part Number STH025 8/12
Preventative Maintenance Cleaning
Procedure
This procedure cleans all components in the water
flow path, and is used to clean the ice machine
between the bi-yearly cleaning/sanitizing procedure.
Ice machine cleaner is used to remove lime scale and
mineral deposits. Ice machine sanitizer disinfects and
removes algae and slime.
NOTE: Although not required and dependant on your
installation, removing the ice machine top cover may
allow easier access.
1. Ice must not be on the evaporator during the
clean/sanitize cycle. Follow one of the methods
below:
•
Press the power switch at the end of a harvest
cycle after ice falls from the evaporator(s).
•
Press the power switch and allow the ice to melt.
2. Open the front door to access the evaporator.
!
Caution
Never use anything to force ice from the
evaporator. Damage may result.
Summary of Contents for b970 series
Page 2: ......
Page 28: ...28 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 58: ...58 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 210: ...210 Part Number STH025 8 12 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 250: ...250 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 252: ...252 Part Number STH025 8 12 I0300 I0450 I0500 I0520 Self Contained Air Water cooled 1 Ph ...
Page 253: ...Part Number STH025 8 12 253 I0320 Self Contained Air Water cooled 1 Ph ...
Page 254: ...254 Part Number STH025 8 12 I0500 Remote Air cooled 1Ph ...
Page 255: ...Part Number STH025 8 12 255 I0600 I0850 I1000 I1200 Self Contained Air Water cooled 1 3 Ph ...
Page 256: ...256 Part Number STH025 8 12 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Page 257: ...Part Number STH025 8 12 257 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Page 258: ...258 Part Number STH025 8 12 I1400 I1800 Remote Air cooled 1 3 Ph ...
Page 262: ...262 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 263: ......