Part Number STH025 8/12
43
Step 1
Open the front door to access the evaporator
compartment. Ice must not be on the evaporator
during the clean/sanitize cycle. Follow one of the
methods below:
•
Press the power switch at the end of a harvest
cycle after ice falls from the evaporator(s).
•
Press the power switch and allow the ice to melt
.
Step 2
Remove all ice from the bin/dispenser.
Step 3
Press the clean switch. Water will flow
through the water dump valve and down the drain.
Wait until the water trough refills and the display
indicates add solution (approximately 1 minute), then
add the proper amount of ice machine cleaner.
!
Caution
Never use anything to force ice from the
evaporator. Damage may result.
Model
Amount of Cleaner
I0300/I0320/I0520
3 ounces (90 ml)
I0450/I0500/I0600
I0850/I1000/I1200
5 ounces (150 ml)
I1400/I1800
9 ounces (265 ml)
Summary of Contents for b970 series
Page 2: ......
Page 28: ...28 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 58: ...58 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 210: ...210 Part Number STH025 8 12 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 250: ...250 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 252: ...252 Part Number STH025 8 12 I0300 I0450 I0500 I0520 Self Contained Air Water cooled 1 Ph ...
Page 253: ...Part Number STH025 8 12 253 I0320 Self Contained Air Water cooled 1 Ph ...
Page 254: ...254 Part Number STH025 8 12 I0500 Remote Air cooled 1Ph ...
Page 255: ...Part Number STH025 8 12 255 I0600 I0850 I1000 I1200 Self Contained Air Water cooled 1 3 Ph ...
Page 256: ...256 Part Number STH025 8 12 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Page 257: ...Part Number STH025 8 12 257 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Page 258: ...258 Part Number STH025 8 12 I1400 I1800 Remote Air cooled 1 3 Ph ...
Page 262: ...262 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 263: ......