Part N
umber ST
H025 8/12
131
Freeze Cycle
Discharge Pressure
_______ ______ ______
1 minute Middle End
into cycle
If discharge pressure is High or Low refer to freeze cycle high or low discharge pressure problem checklist
page 140 to eliminate problems and/or components not listed on this table before proceeding.
Freeze Cycle
Suction Pressure
_______ ______ _____
1 minute Middle End
If suction pressure is High or Low refer to freeze cycle high or low suction pressure problem checklist
page 144 to eliminate problems and/or components not listed on this table before proceeding.
Suction pressure is
High
Suction pressure is
Low
or Normal
Suction pressure is
High
Suction pressure is
High
Wait 5 minutes into the
freeze cycle.
Compare temperatures of
compressor discharge line
and
both harvest valve
inlets.
The harvest valve inlet is
Hot
-and-
approaches the
temperature of a
Hot
compressor discharge
line.
The harvest valve inlet
is
Cool
enough to hold
hand on
-and-
the compressor
discharge line is
Hot.
The harvest valve inlet
is
Cool
enough to hold
hand on
-and-
the compressor
discharge line is
Cool
enough to hold hand on.
The harvest valve inlet
is
Cool
enough to hold
hand on
-and-
the compressor
discharge line is
Hot.
SINGLE EVAPORATOR, DUAL EXPANSION VALVE
SELF CONTAINED AIR, WATER & REMOTE CONDENSER
Operational Analysis
1
2
3
4
Summary of Contents for b970 series
Page 2: ......
Page 28: ...28 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 58: ...58 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 210: ...210 Part Number STH025 8 12 ACCESS REMOTE RECOVERY EVACUATION CONNECTIONS ...
Page 250: ...250 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 252: ...252 Part Number STH025 8 12 I0300 I0450 I0500 I0520 Self Contained Air Water cooled 1 Ph ...
Page 253: ...Part Number STH025 8 12 253 I0320 Self Contained Air Water cooled 1 Ph ...
Page 254: ...254 Part Number STH025 8 12 I0500 Remote Air cooled 1Ph ...
Page 255: ...Part Number STH025 8 12 255 I0600 I0850 I1000 I1200 Self Contained Air Water cooled 1 3 Ph ...
Page 256: ...256 Part Number STH025 8 12 I0600 I0850 I1000 Remote Condenser Air cooled 1 3 Ph ...
Page 257: ...Part Number STH025 8 12 257 I1400 I1800 Self Contained Air Water cooled 1 3 Ph ...
Page 258: ...258 Part Number STH025 8 12 I1400 I1800 Remote Air cooled 1 3 Ph ...
Page 262: ...262 Part Number STH025 8 12 This Page Intentionally Left Blank ...
Page 263: ......