32
MARA PIGGYBACK SERVICE MANUAL
10
Set the lockout switch to Party
Mode. Compress the damper body
and note any bubbles rising up in
the reservoir. Repeat as needed.
Close the LSC adjuster, open the
HSC adjuster and repeat. This will
expel any air trapped under the
HSC shim stack. Repeat steps 8-9
as needed if there is any suspicion
of air remaining in the system.
With Work Mode engaged, the
damper should be very firm.
Fully extend the damper body.
Fill the reservoir completely
full with damper oil.
11
12
The large cup side of the SKF
IFP will be facing up (towards
the gas charge side). Use 1
edge, and “scoop” the shallow
face of the piston into the oil,
allowing the small air pocket
to clear before submersing.
Stop when the leading edge
of the IFP is engaged on the
primary inner diameter of the
reservoir below the threads.
bleed and fill