Attaching the feet
Remove the 4 transit feet and store in the accessory
case. The machine comes supplied with 4 feet in the
accessory case. 2 small and 2 large. The large
are
placed on the rear mounting holes and the 2 small
ones are placed in the very front mounting holes.
The extra holes near the middle are only used for 2
of the 4 transit feet.
The Accessory Tray
The machine comes with a wooden accessory tray,
that has a lid. All supplied accessories will be in this
tray. It also functions to store screws clips and
transit feet, should the machine ever need to be
repacked into it's protective shipping case.
Mains Water Connection
The Vesuvius is supplied ready for a mains water
connection or internal tanked operation.
As the
Vesuvius only uses the mains water connection
to fill it's internal tank and the pump always
draws from the internal tank. A pressure reducer
is not required when plumbing in.
Use the flexible
hose provided with the machine, connect it to a
connection hose 3/8” male with a shut off valve. The
use of a water softer or filtration system, is advised.
The drip tray can be plumbed to the waste or left
unplumbed.
To plumb to the waste use the flexible hose provided
and remove the rubber stopper in the pipe at the
rear of the tray. The mains water connection is
underneath the machine towards the back.
The internal tank
The internal tank is accessed by opening the left
side panel using the opening latch.
Remove the tank and wash in warm soapy water
before first use. Ensure all tubes are replaced in the
tank. The longer of the 2 tubes must reach all the
way to the bottom of the tank (this is the pump inlet),
make sure the small particulate filter is in place. The
shorter tube is the vent tube from the safety release
valve and need not reach the base of the tank.
Routing the safety pressure release vent valve to the
water tank, protects both you and the machines
electronics if a fault causes any high pressure
venting of steam from the safety valve.
Electronic selection -Tanked or mains
plumbed
There is a switch under the machine at the rear,
after connecting to the water main, this needs to be
switched on...the switch will light when in the on
position.