46
M&R Companies 440 Medinah Rd. Roselle, IL 60172 USA
Tel: +630-858-6101 Fax: +630-858-6134
V.120617
Daily
WARNING:
To prevent possible injury to personnel and/or damage to the equipment, lock
out and tag the electrical service to the equipment.
Printing Nozzle Checks
Nozzle Checks should be performed on a daily basis, usually each morning or the beginning of each shift to
confirm the status of the printhead. Nozzle Checks can also be printed anytime there is an abnormality in a
printed image. It is a quick way to confirm whether the printheads are firing at 100%. On the right hand side of the
Main PCS window is the maintenance header bar which is used for Nozzle Checks.
1.
Start by loading a screen into the machine. Then lightly spray tack a piece of paper and adhere it to the
upper right hand corner of the screen. The right edge and leading edge should be in alignment with the
pusher frame below.
2.
In the PCS main window confirm the
Origin for Calibration
box is selected and the
X Origin
is set at
3.00 in (1).
Note: Setting the
X Origin
at 3" inches places the Nozzle Check start position so that it prints on the
upper right hand corner of the paper. For each subsequent nozzle check, increase the
X Origin
1.5".
For example, increasing the
X Origin
to 3" / 4.5’ / 6" / 7.5" / 9" / 10.5" / 12" etc., moves each new
nozzle check across the page to the left.