WARNING: LP Gas is highly volatile and extremely explosive. Do not use
matches or a flame to test for leaks. Use only approved LP Gas leak testing
solution for leak detection. Unapproved solutions can damage copper tubing
and brass fittings. Never attempt to adjust LP Gas regulators. Only qualified
personnel should perform any maintenance or repair to the LP Gas system.
The liquid petroleum (LP) gas system furnishes the fuel for cooking, heating, and hot water.
LP Gas can also be used as an alternate energy source for refrigeration. LP Gas is a clean,
efficient, safe form of energy when proper handling and safety precautions are observed.
The gas is stored under extreme pressure in the tank, with space in the tank to allow for
expansion into vapor. This vapor is reduced in pressure by passing through a regulator. This
reduction in pressure is a two step process which assures consistent pressure for use,
regardless of outside temperatures, weather, or altitude.
NOTE: For detailed information regarding LP Gas, and it’s use consult a qualified
LP Gas service representative.
NOTE: Even though the tank is equipped with an automatic 80% shut-off which
prevents over-filling beyond 80% tank capacity, it is a good idea to have the supplier
monitor the 20% liquid gauge, and stop the filling process if liquid does appear.
9-1
2005 PRESIDIO
LP GAS SYSTEMS
Summary of Contents for 2006 Presidio
Page 1: ...2005 PRESIDIO 08 2005 Revision 1...
Page 2: ...2005 PRESIDIO...
Page 4: ...2005 PRESIDIO...
Page 6: ...2005 PRESIDIO...
Page 7: ...2005 PRESIDIO...
Page 8: ...2005 PRESIDIO...
Page 12: ...TABLE OF CONTENTS 2005 PRESIDIO...
Page 22: ...X 2005 PRESIDIO INTRODUCTION...
Page 36: ...1 14 IDENTIFICATION SAFETY 2005 PRESIDIO...
Page 62: ...3 12 DASH CONTROLS INSTRUMENT PANELS 2005 PRESIDIO...
Page 96: ...7 14 ELECTRICAL SYSTEMS 2005 PRESIDIO...
Page 116: ...9 10 LP GAS SYSTEMS 2005 PRESIDIO...