![Mammut Barryvox-S Reference Manual Download Page 13](http://html.mh-extra.com/html/mammut/barryvox-s/barryvox-s_reference-manual_699082013.webp)
EXTENDED REFERENCE GUIDE
BARRYVOX
®
S
13
SETTINGS
Time for Auto-Revert to SEND
Auto-revert to SEND switches the transceiver from SEARCH
mode to SEND mode or from Rescue-SEND mode to SEND
mode if there is no user interaction or major motion for a
specifi c amount of time. The default setting of 4 minutes is
appropriate for most users, shorter times tend to lead to more
frequent, involuntary switchovers. As rescuers which inatten-
tively switch to SEND mode may cause severe distraction to
an ongoing search, only change this setting if you have an
important reason to do so.
Vital Data
Your Barryvox
®
S detects slight motion of the body, such as a
pumping heart or breathing lungs. Any motion is interpreted as
a vital sign, for further information on vital data see chapter “Vi-
tal Data Detection”. While you are buried, the device transmits
your vital data via the W-Link radio connection to the rescuers
(default setting). In SEARCH mode, the Barryvox
®
displays the
vital status, provided the sender has enabled the W-Link and
the ability to transmit vital data.
If you do not wish to have these data transmitted, you can
disable this feature. Utilizing vital data as one triage criteria can
increase the ratio of survival in a search where rescue resourc-
es are stretched – for this reason only change this setting if you
have an important reason to do so.