AF-JA/JZ-150129
Hold time:
this determines the time the fitting remains at 100% level on
motion detection and is set with DIp switches at the sensor
itself, refer to figure.
the following settings are available:
I – 5s
II – 30s
III – 1 minutes
IV – 5 minutes
V – 10 minutes
VI – 30 minutes
Detection Area:
this determines the effective range of the motion detector
and is set by DIp switches at the sensor itself, refer to figure.
note that reducing the sensitivity will also narrow the detection
range.
the following settings are available:
I – Detection range 100%
II – Detection range 75%
III – Detection range 50%
IV – Detection range 25%
V – Detection range 10%
Daylight sensor:
this setting holds off the 100% light output should there be
sufficient daylight and is set using DIp switches at the sensor,
refer to figure. the following settings are available:
I – 2 lux
II – 10 lux
III – 30 lux
IV – 50 lux
V – disable
SEttInGS
*In disable mode the lamp(s) will always be on with motion detected and operate at 100% light output, even in bright
daylight.
Detection Area
1
2
3
I
100%
II
75%
III
50%
IV
25%
V
10%
Hold time
1
2
3
4
I
5s
II
30s
III
1min
IV
5min
V
10min
VI
30min
Daylight Sensor
1
2
3
I
2lux
II
10lux
III
30lux
IV
50lux
V
Disable
To connect several control gears with 1 sensor (ON-OFF function), the wiring should be:
this sensor is suitable for indoor use. Max. installation height is 6 meters.