Imperial Carousel - Page 4
Hood Assembly
Position the hood on the basic unit. Secure hood to basic
unit using the 13 sheet metal screws provided.
IMPORTANT:
Failure to install these screws will result in
permanet damage to the unit and void the warranty.
Hood
Sheet Metal Screws
13- 14 x 1/2 Hex.
Basic Unit
All Screws Must Be Installed
Hearth Requirements
A fl oor protector is required to
protect the fl oor in front of the
fi replace opening from sparks.
The fl oor protector must be a
minimum of 2 1/2 inch thick com-
mon solid brick over 26 gauge
sheet metal or equivalent.
The fl oor protector must extend
a minimum of 16 inches in front
of the fi replace opening and
8 inches to either side of the
fi replace and 8 inches behind
the back of the unit. Refer to
Figure #3.
8"
8"
48"
54"
16"
Figure 3
54" Diameter Circle Hearth.
8" Minimum is measured from
the fi re-box
8"
8"
8"
16" From Door
Fire Bowl
Door
8"
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
This stove must be connected to (1) a chimney com-
plying with the requirements for Type HT chimneys in
the Standard for Chimneys, Factory-Built, Residential
Type and Building Heating Appliance, UL 103, or (2) a
code-approved masonry chimney with a fl ue liner.
Chimney Connector Installation
It is required to install a 8 inch all-fuel class "A" chim-
ney system prior to the chimney connector installa-
tion. The connector pipe included with the Imperial is
1 - 8" x 30" starter pipe, and 1 - 8" x 30" slip connec-
tor. The slip connector is identifi ed by 3 holes at the
top of the pipe. The slip connector has one fl air at
the top with the 3 holes. The bottom is smooth. The
starter pipe section has fl airings at both ends. The
male end is always at the bottom.
Simpson Dura-Vent Chimney System
It is required to use a Dura-Vent Universal Connector
part number
8DVL-ADC or 8878 Adapter
to install the
chimney connector.
1. The universal connector is installed into the support
box. The 8" x 30" slip pipe is then connected to the
universal connector.
2. The 8" x 30" starter pipe section is then slid over the
slip connector pipe. Slide the 30 inch pipe over the
slip pipe only far enough as necessary to facilitate
installation of the 8" x 30" starter pipe in to the unit.
3. There must be a minimum of 2 inches of overlap be-
tween the 8" x 30" and 8" x 30" slip connector pipe.
Metalbestos or Security ICC EXCEL
When using Metalbestos or Security chimney systems it
is required to use the Metalbestos DS-CPA Single Wall
Conector pipe. Security users must use the EX adapter.
1. Installation of the Metalbestos DS-CPA or the Secu-
rity EX adapter must be done fi rst.
2. Attach the 8" x 30" slip connector to the DS-CPA or
EX adapter with 3 - #8 x 3/8 inch screws.
3. The 8" x 30" starter pipe section is then slid into the
slip connector pipe. Slide the 30 inch pipe into the
slip pipe only far enough as necessary to facilitate
installation of the 8" x 30" starter pipe into the unit.
4. Slide the 8" x 30" pipe down onto the Imperial.
5. There must be a minimum of 2 inches of overlap be-
tween the 8" x 30" and 8" x 30" slip connector pipe.
Other Chimney Systems
There are many other manufacturer's of chimney sys-
tems. It is beyond the scope of this publication to cover
installation with all of the diff erent systems available.
Most systems have a method of connection to the Impe-
rial's connector pipe. Confi rm installation procedures
with your dealer or the manufacturer of the chimney
system you have purchased.