4. FEATURES OF OMEGA ELECTRIC BOILER

Maktek Omega Boiler uses ONLY electricity as fuel.

The device is equipped with many safety functions to provide risk free operation. 

Operates with 99% efficiency.

Eco-friendly, 0 emissions.

Due to its quiet operation and lack of connections like chimneys, it can be mounted in 

living areas easily.

It offers an aesthetic look with its minimized dimensions and exterior design.

Running costs are 32% lower than diesel boilers and 25% lower than LPG boilers. 

Provides hot water in constant temperature at set value.

Heating system can quickly enter the regime and heat the house.

Protection against high pressures with 3 bar safety valve.

Manometer

3-stage circulation pump.

1 bar set safety switch.(protection againts running without water)

Built-in RCD (short circuit relay) provides electrical protection and safe operation.

Automatic by-pass system.

Modulation according to room temperature (with optional room thermostat)

Electronic water temperature control with NTC system.

Electronic temperature adjustment thermostat.

Limit thermostat against overheating.

Short-circuit thermostat for increased protection.

Anti-jamming system. Operating in every 24 hours to prevent pump jamming.

Frost protection system.

Wide capacity range, from 6 kW upto 100 kW. Meets a wide range of heating

requirements.

12

Summary of Contents for Omega 6

Page 1: ...rev no 01 05 2018...

Page 2: ...NS 10 3 7 FILLING WATER TO THE SYSTEM 11 3 8 STARTING UP 11 3 8 1 PRE CONTROLS BEFORE STARTING UP 11 3 8 2 FIRST OPERATION 11 3 8 3 CIRCULATION PUMP PRESSURE CURVE 12 4 FEATURES OF OMEGA ELECTRIC BOIL...

Page 3: ...d this guide carefully This guide is an important source of installation and technical features that you can benefit from It is very important for you autorized services in terms of the information it...

Page 4: ...ation Damage to the furniture or floor or animals resulted from falling objects from device because of vibration Do not climb on the device Personel injury as a result of falling down with device or f...

Page 5: ...ators connected to the system and provides hot water by heat exchanger Installation and services must be in accordance with recent standarts and announced directives Our company is not responsible for...

Page 6: ...2 2 COMPONENTS OF THE BOILER 5...

Page 7: ...ere is no hot water production even when the hot water tap is opened TEST Mode of adjustment by AUTORISED SERVICE during first installation or maintance Users should not use this position during opera...

Page 8: ...rgy cable dimensions should be chosen from the technical specifications table in this manual and must be connected by a qualified electrician WARNING Do not operate the boiler before venting the air f...

Page 9: ...ace must be left around the for the authorized service to intervene in the event of a technical breakdown or maintenance You can find the minimum spaces required for installation in the below diagram...

Page 10: ...e above the capacity of the pump must be avoided You can see the pump capacities from the pump pressure curve When there is a pressure increase at heating system the security ventile operates in order...

Page 11: ...OLS BEFORE STARTING UP A Make sure all air is vented from the system radiators and the boiler and all air vents are closed B Check the system pressure from the manometer Must be 1 2 1 5 bars C Remove...

Page 12: ...ega Boiler Circulation pump has 3 speed options You can choose the required pump speed according to the resistance of your installation You can use the below diagram for deciding the pump speed Water...

Page 13: ...an quickly enter the regime and heat the house Protection against high pressures with 3 bar safety valve Manometer 3 stage circulation pump 1 bar set safety switch protection againts running without w...

Page 14: ...5 TECHNICAL TABLE 13...

Page 15: ...6 ELECTRICITY CONNECTION DIAGRAM 14...

Page 16: ...r the boiler will not operate and the H3 warning code will appear on the digital display preventing damage which causes from running without water What to Do The heating system pressure is increased b...

Page 17: ...ves are switched off there is an automatic by pass system in order to provide of passing of minimum water flow in order to prevent rapid over heating of the boiler 8 MAINTENANCE We recommend that the...

Page 18: ...ansport 7 Damages caused by the use of lime water in hot water circulation ideal water hardness will be 15 20 French hardness 8 First operation and interventions by people other than the authorized se...

Page 19: ......

Reviews: