Fault: The boiler is operating normally, but the radiators are not warming up.
Reason: 1- The circulation pump may not work. Check that the pump tightness by rotating the
screwdriver head on the pump shaft.
2- Air was collected in the radiators. Take the air from the radiators.
If your device does not work when the above procedures are performed, we recommend you to
contact with an authorized service.
D. WARRANTY CONDITIONS
In order for the boiler to work well and efficiently for many years:
* YOU MUST MAKE PERIODIC MAINTENANCE EVERY YEAR FOR VALIDATION OF 3 YEARS
WARRANTY.
In order for your warranty terms to continue for the first three years, you are required to make
periodic maintenance every year. You should keep your annual periodic maintenance coupons
which are signed, stamped by autorized srevices after care.
DO NOT PAY THE FEES WITHOUT SEEINGTHE CURRENT PRICE LIST IN YOUR SERVICE.
E. FUEL TYPE
Use diesel as fuel. Be careful that the diesel is free from foreign substances such as water, oil,
sediment.
MAKTEK CAN NOT BE HELD RESPONSIBLE FOR ANY DAMAGES CAUSED FROM USING DIESEL WITH
ADDITIVES.
POINTS TO BE CONSIDERED BY INSTALLATOR FIRM
TECHNICAL INFORMATION AND INSTALLATION INSTRUCTIONS
1- Technic Information
-Draught need: Chimney draught need must be minimum -2mm ss.
-Combustion chamber pressure: Must be -3mm ss
-Chimney gas outlet temperature: Must be maximum 200°
-Mass of chimney gas: 20m³/h (-10)(+10) according to chimney draught
- Chimney outletconnection diameter : 130 mmØ
-Water side resistance:10 m bar
-Maximum heat power: 20.000Kcal/h
-Relativistic boiler loss: Maximum 12%
-Boiler gaz volume: 20 liters.
-Temperature control space: Δt:6°C
-Combustion room dimensions and volume:23x34=15lt
9