Example:
Qk= 20.000 kcal/h (boiler capacity)
h= 15m (chimney vertical height)
F= What should it be?
g) The chimney should be kept away from the outer wall and generally kept at the mid-point of the
building, ie at the highest part of the roof and at least 80 cm away from the roof.
h) The chimney section can be calculated using the formula given below.
Make the chimney connection in the frame of this information and check the chimney draught.
3- The safety thermostat is set to 90°C. Make sure that the setting is not changed for any reason.
4- If there is no separate place to install the boiler in the apartment, the boiler should be placed in
bathroom, kitchen or balcony. If it is placed in a balcony, it should be kept in a division. The boiler
should never be placed in the bedroom.
5- Check the fuel connection line again to prevent leaks.
6- Your system has close expansion tank. Ensure that the installation is filled with water, that the
air collected in the radiators are thrown out, and that the air in the boiler is taken out before
starting to use.
7- Grounded plug is supplied with the boiler. Ensure that this plug is used with a grounded socket.
8- Always mount the plastic reinforced feet in place while installing the boiler and adjust the
settings to keep the boiler stable.
9- You must also sign the Warranty Document by submitting the date of delivery and supply the
fuel and make authorized the service to start running of boiler. Deliver it to the user in working
condition.
11