MAKTEK

 Boiler has a high efficiency construction and provides economy by burning fuel fully.

The burner used in MAKTEK Boiler, is a high-quality burner with superior technology. It provides 
high efficiency combustion, which provides the fuel air mixture at optimum concentration.

GENERAL WARNINGS AND RECOMMENDATIONS

The points to be followed by the user during oprating and maintenance are explained in this  

manual.
The following suggestions and warnings must be cared in terms of safety and efficiency of the 

system.

POINTS TO BE CONSIDER BY USERS

1- Receive your boiler in operative condition together with your installer system 

2- Put your boiler in places where the plumber is suggests.
3- The boiler capacity is in 20.000 Kcal heating power, and heating more or less is linked to the 

amount of radiator to be selected. In this regard, consider the suggestions of your plumber.
4- Prepare the chimney, chimney connection, water, fuel and electricity connection when the 

central heating system is installed. Take care that the chimney connection is at the shortest 
distance.

5- In the summer months when the boiler is not used, run the boiler at least once a month for 1-2 
minutes. This will remove the chance of the circulation pump becoming trapped in the winter.

A.  OPERATION OF THE BOILER

1-Check hydrometer to see if the expansion is filled with water. Do this check at any time during 

the working period.
2- Check the fuel tank if it is full with diesel fuel. Do not use the fuel in the tank until if finishes for 

fuel line not to make air.
3- Set your thermostat at the desired temperature (for ex. 50°- 60°-80°)

4- Check that the valve on the fuel line or at the fuel tank outlet if it is open.
5- Run your device by pressing the main control button (on the fron conrol panel )to ON position.

                                                                               

   2

Summary of Contents for 20 MK

Page 1: ...20 25 35 MK Installation Operation and Maintenance Instruction ECONOMIC FULL AUTOMATIC ELECTROCNIC IGNITION FULL SAFE WIDESPREAD SERVICE NETWORK...

Page 2: ...unt of radiator to be selected In this regard consider the suggestions of your plumber 4 Prepare the chimney chimney connection water fuel and electricity connection when the central heating system is...

Page 3: ...ly be operated for hot water Selector switch position on the electric panel must be placed at mode 2 MAKTEK Cenrtal Heating Boiler with Hot Water automatically starts to produce hot water Shortly afte...

Page 4: ...nd turbulators First the cable headers with socket are removed from the double electrode Then the screw holding the turbulator is loosened and turbulator demounted from its place The electrode holder...

Page 5: ...ment and water that accumulate on the bottom of the boiler by opening draining valve 3 Clean the diesel filters at the outlet of the tank every 30 days After the filter is cleaned drain the air of the...

Page 6: ...check for leaks PHOTOCELL CLEANING 1 Stop running of device 2 Remove photocell by pulling it to the back side 3 Clean the glass part of the photo cell with a clean dry cloth and replace it SOOT CLEAN...

Page 7: ...the electrode adjustment is not disrupted If the setting is corrupted at the time of cleaning make the adjust as shown in picture D 7 Insert the cover that has barrel and place the burner in it BURNER...

Page 8: ...mp of the device is on and not working Press the reset button three times for five minutes If the device does not work again proceed as follows Reason 1 Diesel s over Check it out 2 The voltage is low...

Page 9: ...enance coupons which are signed stamped by autorized srevices after care DO NOT PAY THE FEES WITHOUT SEEINGTHE CURRENT PRICE LIST IN YOUR SERVICE E FUEL TYPE Use diesel as fuel Be careful that the die...

Page 10: ...in order to dispose of the dirty air that can be collected in this area it is necessary to find open air gap at the ceiling that would have the 25 of the cross section of the smoke pipe c A heating s...

Page 11: ...hroom kitchen or balcony If it is placed in a balcony it should be kept in a division The boiler should never be placed in the bedroom 5 Check the fuel connection line again to prevent leaks 6 Your sy...

Page 12: ...5 2 8 2 95 3 07 3 2 3 33 Power 27 87 29 65 31 43 33 21 34 99 36 41 37 95 39 49 0 85 Capacity 2 75 2 92 3 1 3 27 3 45 3 6 3 75 3 9 Power 32 62 34 63 36 76 38 78 40 92 42 69 44 47 46 25 1 00 Capacity 3...

Page 13: ...w Example Desired power 29 KW The nearest value is 28 70 kW to 12 bar pump pressure This value corresponds to a 0 60 GPH injection When you look at the vertical column appropriate pump pressure will b...