background image

 

19 

 

Turning On the Device:  

The  ""ON/OFF"  button  on  the  device  is 
activated in order to turn on the device. 

 

 

Checking Battery Status:  
 

Check  the  battery  charge  indicator  in  the  middle  of  the  device.  If  three 
lights are on, the battery is full. If two lights are on, the battery is half full 
and if there is only one light on, the battery is about to be dead. If three 
lights  are  on  and  off  periodically,  the  device  power  is  not  enough  to 
operate  the  device.  If  there  is  no  light  on,  the  battery  is  flat.  When  the 
battery  charge  is  weak,  the  device  settings  change,  which  may  cause 
some  errors.  Therefore,  pay  attention  to  keeping  the  battery  full. 
Especially, take care not to use the device and charge the battery when 
only one light is on. If the battery is flat or is not powerful enough, turn off 
the device and connect the charger to the battery to charge it.  

 

 
 

 

 

 

 

 

FULL  

HALF  

LOW 

EMPTY  

Summary of Contents for JEOTECH

Page 1: ...1...

Page 2: ...CONTENTS Jeotech Accessories and Components 5 Jeotech System Unit and Joystick 8 Assembly and Charging the Battery 11 Jeotech Using Phases 17 Ground Setting 21 Ground Setting Phases 22 Explore Mode 2...

Page 3: ...3 WARNINGS CAUTION PLEASE DO NOT START ASSEMBLING OR USING BEFORE READING THE WARNINGS SECTION...

Page 4: ...3 DO NOT USE ANY OTHER DETECTOR OR A DEVICE THAT EMIT MAGNETIC WAVES WITHIN 10 m PROXIMITY OF THE DEVICE 4 PREVENT THE DEVICE FROM ABRUPT MOVEMENTS AND POSSIBLE SHOCK 5 DO NOT EXPOSE THE DETECTOR HEAD...

Page 5: ...5...

Page 6: ...6 JEOTECH ACCESSORIES AND COMPONENTS...

Page 7: ...where the detector sockets earphone socket and battery socket are located and where measurement results are evaluated and displayed on the LED monitor on joystick 2 210x315 Detector Head It is the an...

Page 8: ...utput DC 9 12 V 400 mA Charge duration 10 hours 5 Carrying Case It is a case used for transport and storing of the System Unit the 210x315 Detector Head and accessories 6 Earphone It is the piece that...

Page 9: ...9 JEOTECH SYSTEM UNIT AND JOYSTICK...

Page 10: ...is used for turning on the device 2 GROUND SWITCH The switch that is used for ground setting 3 SENSITIVITY The switch that is used for adjusting the sensivity level 4 SOUND AND LIGHT ADJUSTING SWITCH...

Page 11: ...t is a ferrous metal 4 POWER LIGHT The light shows that the device is on 5 NON FERROUS LIGHT The light shows that the target is a non ferrous metal 6 METAL and MINERAL If there is a metal effect on th...

Page 12: ...12 JEOTECH ASSEMBLY AND CHARGING THE BATTERIES...

Page 13: ...the sleeve The detector head is dismounted from the extension tube when packing in the carrying case Dismantling is carried out as the reverse of the process described above CAUTION Do not take apart...

Page 14: ...Electronic system box The 5 pin plugs shown in the above figure are connected to socket on the system box EARPHONE CONNECTION Enables signal sound to be switched from external loudspeaker to the earp...

Page 15: ...fective battery is connected to the charger green light on the charger blinks 5 times a short beep tone is heard and the green light turns into red blinks repeatedly and frequent beeps are heard In su...

Page 16: ...nt When the setup is completed a short beep sound is heard and charging starts ATTENTION During the setting period do not disconnect the battery from the charger During the charging process the blinki...

Page 17: ...17...

Page 18: ...18 JEOTECH USING PHASES...

Page 19: ...out to be dead If three lights are on and off periodically the device power is not enough to operate the device If there is no light on the battery is flat When the battery charge is weak the device s...

Page 20: ...in and Max after the device is turned on and the light level is set NOTE When battery is flat all three BATTERY lights flash and a sound alarm is generated NOTE When search cap breaks down or when the...

Page 21: ...ce unable to detect the target Reset takes place after the search cap is taken to a side off the target Don t forget to reset after every action you take Exercise due care not to reset on the target U...

Page 22: ...objects This should be used to detect the large metals or large holes WHAT IS GROUND SETTING AND HOW IT IS DONE In our country land formation and soil composition vary in relation to regions In some r...

Page 23: ...eliminate ground effect on the device Steps for the Ground Setting 1 The device is turned on 2 The Ground Setting should be made at a spot where one is sure that there is no metal and Cavity If the gr...

Page 24: ...ere is a ground effect on the device the METAL and MINERAL or CAVITY and MINERAL lights of the device will be on 6 In case of a warning for METAL and MINERAL a Raise the search cap of the device by 40...

Page 25: ...alerts e In such a case raise the search cap to a distance of 40 cm Press the ground button a few times in direction and reset Take the search cap close to the ground by the same distances again If t...

Page 26: ...rform a search on such ground d If the ground effect continues the device will continue to keep the Cavity and Mineral lights on and to generate a sound alert e In such a case raise the search cap to...

Page 27: ...h with a single light on the Metal and Mineral or Cavity and Mineral side NOTE As the sensitivity levels are reduced there is a decline in sensitivity in detecting metals NOTE The search must be condu...

Page 28: ...28 SEARCH WITH A DEVICE WITH GROUND SETTING...

Page 29: ...device detects Cavity the CAVITY AND MINERAL lights on the screen will be on depending on the signal strength and a sound alert will be generated If our target is metal or Cavity then the device gener...

Page 30: ...to the side away from the target when you receive a metal signal and move over the target again after pressing the SCAN button in this case if the metal is a valuable metal NONFERROUS light will be on...

Page 31: ...31...

Page 32: ...32...

Reviews: