background image

 

 

 

Misprints and printing errors reserved 

During

 installation, the filter 

may not be connected to the 
power supply. Remove the plug 
from the socket and make sure 
that the filter cannot be 
activated. In order to prevent 
injury, you must assure that 
you are absolutely unable to 

reach the rotating parts of the filter with your hands and 
fingers once it has been connected to the power supply. 

 

7. Commissioning of the filter 

NEVER USE THE DEVICE WITHOUT WATER FLOW. 

7.1 Positioning of the filter 

 

You must strictly follow below mentioned 
regulations to work safely and prevent damage to 
the device.  
Make sure that the substrate is level and 
sufficiently solid; a concrete slab is preferred.  
 

 

When checking whether the rinse pump or motor 
of the drum still works, the lid must always be 
closed. Never put your hands in the filter, or try to 
stop the drum.  
 

 

The rinse pump must always be below the water 
level before it is activated. Otherwise it will be 
damaged irreparably due to running dry or 
overheating. Damage to the rinse pump as a result 
of running dry will not be covered by the warranty.  
 

 

The electronics must hang in a dry and well 
ventilated space. The temperature of the space 
with the electronics must be between 2 and 30 °C. 
In case of higher temperatures, the electronics 
cannot get rid of its heat as a result of which it 
may get damaged.  
 

 

The electronics contains switching components and 
must be placed in an interference-free room. 
 

 

Certain pumps or UV-units may adversely affect 
the functioning of the electronics.  
 

 

In case of frost,

 the filter must be 

protected against freezing. If the 
filter is being activated outdoors, 
all pipes must be empty. If the 
filter remains operative, the 
pipes for the rinse water must 
be protected against freezing.  
 
 
 

Damage as a result of freezing of water is not covered by 
the warranty.  

7.2 Connecting Gravity 

If the water flows into the drum with gravity flow, the 
maximum water level most be properly aligned with the 
drum. The maximum and minimum water levels are 
indicated on the inside of the filter and it should be 
between them, preferably as close to the maximum level 
as possible (see image). The filter has 110 mm entries and 
110 mm exit(s). In addition, there is a connection for the 
rinse pump for the Bio-drum 30.  

Please note: 

For installation on gravity-basis, sufficient water feed is 
very important for proper functioning of the filter!  

 

If there is insufficient water supply, due to an incorrectly 
installed system, there is a risk of the rinse pump running 
dry and a very frequent activation of the rinse cycle.   

A rule of thumb is that per 110 mm of pipe, approximately 
10 m3/hour can be moved in a gravity-setup. However, 
this quantity largely depends on the length of the pipe and 
the maximum height difference between the pond water 
and the filter. In some cases only 3 m3/hour can be 
moved. 

 

 

 

1

: Example of gravity setup Biodrum 100

 

2

: Example of gravity setup Biodrum 100

 

Summary of Contents for Bio30

Page 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information...

Page 2: ...5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil fr...

Page 3: ...th regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other v...

Page 4: ...ject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve th...

Page 5: ...a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to preven...

Page 6: ...s contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be pr...

Page 7: ...ed This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that...

Page 8: ...frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned I...

Page 9: ...ng the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electron...

Page 10: ...loat upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed...

Page 11: ...nce and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a man...

Reviews: