background image

 

 

 

Misprints and printing errors reserved 

 

If the float is floating, the system is on stand-by. If the 
float is in the lowest position, the process will commence 
(drum starts rotating and the rinse pump will rinse the 
cloth). This will last for 14 seconds. 

If

 the float remains in the lowest position (and the pond 

pump is on) there will be too little water supply from the 
pond. The drum will rinse for 30 seconds (standard value) 
and then switch to dry-running mode.  
This is to protect 
your pond pump. 
Once the float goes 
back to normal 
position (it will float 
again because 
sufficient water flew 
into the filter) the 
pump will activate 
after 5 minutes 
(standard value). 

7.2.6 Control electronics 

The control electronics has protection class IP54. 

Electrical installations must always comply with the 
national and international requirements/guidelines.  

Only open the casing of the electronics to 
connect the float and magnet contact or to 
set the parameters. When connecting the 
float and magnet contact, disconnect the 
device from the power supply before 

connecting it! Changing the parameters is done at own risk 
in case the power supply is connected. Take care of 
electrical hazard when opening.  

The control cabinet must be connected 
to an approved, earthed socket. The 
electronics must be installed vertically. 
The electronics may not be assembled 
unprotected during rain. Per connected 
side, a maximum of 660 W of auxiliary 

equipment may be connected.  

Functions of the green button: 

Press 1 time:    

 

Filter will start to rinse. 

Quickly press 2 times:    

Filter and duct will rinse* 

Quickly press 4 times:   

Filter into emergency mode  

                                             Periodic rinsing. 
                                             If float is defective. 

Press for 3 seconds: 

 

Rinse counter reset. 

Press for 8 seconds: 

 

Text message module 
sends (test) alarm. 

While pressing: 

 

Total number of rinses       
visible on screen. 

 

Connection 1-2:

 Float switch 

Connection 3-4:

 Lid of magnet contact. This is a 

protection for opening the lid. If the lid is opened, the 
drum filter will not rinse. 

Display on white:

 

Filter is operational 

Display red:

 

Lid is open and drum filter will not rinse! 
Pond pump will keep running. This is only when the 

Float is 

in ‘

rinse

’ 

position, pond pump is on. 

Drum is rotating and rinse pump rinses the 
cloth. If the float remains in this position for 
30 seconds, the electronics will switch to 
DRY-RUNNING MODE. 

Motor 

Pond pump 

Rinse pump 

Summary of Contents for Bio30

Page 1: ...1 Misprints and printing errors reserved INSTALLATION AND USER GUIDE FOR MAKOI DRUM FILTERS AND BIODRUMS Scan the QR code for even more information...

Page 2: ...5 7 Commissioning of the filter 6 7 1 Positioning the filter 6 7 2 Connecting gravity 6 7 2 1 Setting of sensor float 7 7 2 3 Connecting rinse pump 7 7 2 4 Connecting motor drum filter 8 7 2 5 Coil fr...

Page 3: ...th regard to the usage and the suitability for an application will be accepted only if they fall within the Ma koi specifications specified in writing as for instance stated in this manual Any other v...

Page 4: ...ject to modification The specifications of the filter offer will prevail and are guaranteed 3 GENERAL 3 1 Description of the drum filter The Bio drum and or the drum filter consists of a drum sieve th...

Page 5: ...a maximum residual current of 30 mA DIN VDE 0100T739 Use the device only when connected to a correctly installed socket Keep the plug and the wiring dry Ensure that the cables are protected to preven...

Page 6: ...s contains switching components and must be placed in an interference free room Certain pumps or UV units may adversely affect the functioning of the electronics In case of frost the filter must be pr...

Page 7: ...ed This is indicated on the display Siemens Logo in the Electronics Cabinet 7 2 1 Setting for sensor float Upon delivery the sensor has already been installed for use as gravity and in such a way that...

Page 8: ...frequency Make sure that the coil frequency is not too high If the drum is installed in an existing system the coil frequency will be high over the first days weeks because the pond is being cleaned I...

Page 9: ...ng the parameters is done at own risk in case the power supply is connected Take care of electrical hazard when opening The control cabinet must be connected to an approved earthed socket The electron...

Page 10: ...loat upside down for the drum section at the inlet 1st chamber Please note The float must be installed in reverse because here the circuit is to work reversely And the upper blue caps must be removed...

Page 11: ...nce and cleaning The filters are low maintenance However maintenance and inspection tasks below are required for proper functioning Check the correct functioning of the float every month Perform a man...

Reviews: