3. Wiring Diagram
UT1200
IV. Checklist for testing the machine
➢
Check for correct assembly!
➢
Check the functionality of the machine!
➢
Test speed-adjustment in different switch positions!
➢
Check isolation of machine with high voltage (1500V)!
V. Grease and Glue
Product:
Where used:
1.
Gearbox Grease
Rhenus MSN 2
120g (4,23oz) inside Gearbox Housing
(18)
40g (1,4oz) chamber of motor housing and
thoothing of intermediate wheel
P
9
/ 9
Summary of Contents for UT 1200
Page 2: ...Repair Manual UT1200 P 2 9...